background image

4

ACCESSORIES

KIT NUMBER

KIT NAME

018---B

024---B

030---B

036---B

042---B

048---B

060---B

KAACH1201AAA

CRANKCASE HEATER

X

X

S

S

KAACH1401AAA

CRANKCASE HEATER

X

X

X

KSACY0101AAA

CYCLE PROTECTOR

S

S

S

S

S

S

S

KAAFT0101AAA

FREEZE THERMOSTAT

X

X

X

X

X

X

X

KSAHS1701AAA

HARD START (CAP/RELAY)

X

X

X

X

X

X

X

KHAIR0101AAA

ISOLATION RELAY

X

X

X

X

X

X

X

KSALA0301410

LOW AMBIENT SWITCH

X

X

X

X

X

X

X

KHAOT0201SEC

OUTDOOR THERMOSTAT

X

X

X

X

X

X

X

KHAOT0301FST

OUTDOOR THERMOSTAT

X

X

X

X

X

X

X

KAACS0201PTC

PTC START ASSIST

X

X

X

X

X

X

X

KHALS0401LLS

SOLENOID VALVE

X

X

X

X

X

X

X

KSASF0101AAA

SUPPORT FEET

X

X

X

X

X

X

X

KAATD0101TDR

TIME DELAY RELAY

X

X

X

X

X

X

X

KSATX0201PUR

TXV (HSO)

X

X

X

KSATX0301PUR

TXV (HSO)

X

X

KSATX0401PUR

TXV (HSO)

X

KSATX0501PUR

TXV (HSO)

X

x = Accessory S = Standard

ACCESSORY THERMOSTATS

THERMOSTAT / SUBBASE

PKG.

DESCRIPTION

TSTATBBPRH01---B*

Thermidistat

t

Control — Non---Programmable/Programmable Thermostat with Humidity Control (For use in

Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.)

TSTATBBPHH01---B*

Hybrid Heat

t

(Dual Fuel) Thermostat — Auto Changeover, 7---Day Programmable,

°

F/

°

C, Includes Outdoor

Sensor (TSTATXXSEN01---B)

TSTATBBPHP01---B

Thermostat — Auto Changeover, 7---Day Programmable,

°

F/

°

C, 2---Stage Heat, 1---Stage Cool

TSTATBBNHP01---C

Thermostat — Auto Changeover, Non---Programmable,

°

F/

°

C, 2---Stage Heat, 1---Stage Cool

TSTATBBSHP01

Standard Programmable Thermostat—Manual Changeover, 5---2 Day Programmable,

°

F/

°

C, 1---Stage Heat/

1---Stage Cool

TSTATBBBHP01---B*

Builder’s Thermostat — Heat Pump, Non---Programmable,

°

F/

°

C, 2---Stage Heat, 1---Stage Cool, Manual

Changeover

TSTATXXSEN01---B**

Outdoor Air Temperature Sensor

TSTATXXNBP01

Backplate for Non---Programmable Thermostat

TSTATXXPBP01

Backplate for Programmable Thermostat and Thermidistat

t

Control

TSTATXXSBP01

Backplate for Standard Programmable Thermostat

TSTATXXBBP01

Backplate for Builder’s Thermostat

TSTATXXCNV10

{

Thermostat Conversion Kit (4 to 5 Wire) — 10 Pack

* Do not use in zoning heat pump applications.
** Outdoor temperature sensor is an accessory for all Bryant electronic thermostats, except the non---programmable air conditioner version and builder;s

thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used

with the HybridHeat

t

(dual fuel) thermostat.

{

Thermostat conversion kit is a 24---vac accessory that can turn a 4---wire thermostat application into a 5---wire application. This kit can also be used to

replace a broken thermostat wire, or add an extra wire when needed.

The outdoor air temperature sensor is included with the Thermidistat Control and HybridHeat

t

(dual fuel) thermostat.

265A

Summary of Contents for PREFERRED 265A

Page 1: ...Quiet Operation S AeroQuiet System IIt for sound as low as 69 dBA S Quiet mount split post compressor grommets S External AeroQuiet muffler S Exclusive AeroQuiet Top design S 8 Pole PSC ball bearing c...

Page 2: ...STAR guidelines for energy efficiency Refer to the combination ratings in Product Data for system combinations that meet Energy Star guidelines STANDARD FEATURES Feature 018 B 024 B 030 B 036 B 042 B...

Page 3: ...ical separation is 200 ft when outdoor unit is above indoor unit and 80 ft when the outdoor unit is below the indoor unit Refer to Accessory Usage Guideline below for required accessories See Long Lin...

Page 4: ...age Heat 1 Stage Cool TSTATBBNHP01 C Thermostat Auto Changeover Non Programmable F C 2 Stage Heat 1 Stage Cool TSTATBBSHP01 Standard Programmable Thermostat Manual Changeover 5 2 Day Programmable F C...

Page 5: ...chance of liquid slugging Usage Guideline Required in low ambient cooling applications Required in long line applications Suggested in all commercial applications 5 Evaporator Freeze Thermostat An SP...

Page 6: ...int Usage Guideline Outdoor thermostat applications where electric heater is capable of 3 stage operation 13 Sound Hood Wraparound sound reducing cover for the compressor Reduces the sound level by ab...

Page 7: ...e for 10 AWG or smaller stranded wire for larger than 10 AWG is used consult applicable tables of the NEC ANSI NFPA 70 Length shown is as measured 1 way along wire path between unit and service panel...

Page 8: ...8 DIMENSIONS 265A...

Page 9: ...UILDING HEAT LOSS UNIT INTEGRATED HEATING CAPACITY MBTUH 0 0 2 9 5 9 8 8 11 7 14 6 17 6 20 5 23 4 kW 265ANA024 A FX4CNF030 265ANA030 A FX4CNF030 265ANA036 A FX4CNF042 265ANA042 A FX4CNF048 265ANA048 A...

Page 10: ...V 13 50 10 80 18 000 3 54 10 900 2 28 8 1 CSPH 2412A 17 600 TDR TXV 15 00 12 00 17 600 3 54 10 300 2 34 8 1 315 A J AV036070 CSPH 2412A 17 700 TDR TXV 15 00 12 00 17 600 3 58 10 300 2 34 8 2 315 A J A...

Page 11: ...66 13 800 2 48 8 4 315 A J AV048090 CSPH 2412A 23 000 TDR TXV 15 00 12 50 23 200 3 64 13 900 2 46 8 3 315 A J AV060110 CSPH 2412A 23 000 TDR TXV 15 00 12 50 23 200 3 64 13 800 2 46 8 4 315 A J AV0661...

Page 12: ...66135 CNPH 3617A 29 000 TDR TXV 15 50 13 00 28 800 3 72 16 800 2 50 8 4 315 A J AV066155 CNPH 3617A 28 800 TDR TXV 15 00 12 50 28 800 3 68 16 800 2 46 8 3 355AAV042040 CNPH 3617A 28 800 TDR TXV 15 50...

Page 13: ...33 000 3 54 19 200 2 40 7 8 315 A J AV060110 CAP 3621A 34 400 TDR TXV 14 50 12 00 33 000 3 48 19 300 2 36 7 7 355AAV042080 CAP 3621A 34 400 TDR TXV 15 00 12 50 33 000 3 50 19 300 2 38 7 7 355AAV060080...

Page 14: ...TXV 15 00 12 50 33 000 3 62 19 400 2 42 7 8 355AAV060120 CSPH 3612A 34 600 TXV 14 00 11 50 34 200 3 60 20 400 2 38 7 7 CSPH 4212A 34 800 TDR TXV 15 00 12 50 33 200 3 64 19 500 2 42 7 8 315 A J AV03607...

Page 15: ...2 355AAV042060 CNPH 4821A 41 000 TDR TXV 14 00 12 00 41 000 3 54 25 200 2 52 8 2 355AAV042080 CNPH 4821A 41 500 TDR TXV 14 50 12 00 41 000 3 58 25 200 2 54 8 2 355AAV060080 CNPH 4821A 41 500 TDR TXV...

Page 16: ...3 355AAV060100 CAP 6021A 48 000 TXV 14 00 12 00 48 500 3 74 30 800 2 54 8 4 CAP 6024A 48 000 TDR TXV 15 00 12 50 47 000 3 74 29 600 2 60 8 3 315 A J AV066135 CAP 6024A 48 000 TDR TXV 15 00 12 50 47 00...

Page 17: ...XV 13 00 10 80 60 000 3 56 37 800 2 50 8 0 CAP 6021A 58 000 TDR TXV 13 50 11 20 59 000 3 52 36 400 2 52 8 0 315 A J AV060110 CAP 6021A 58 000 TXV 13 50 11 20 59 000 3 52 36 600 2 52 7 9 CAP 6024A 58 5...

Page 18: ...15 39 1 67 14 50 14 50 1 87 13 54 13 54 2 09 675 72 22 22 12 10 1 18 21 12 11 69 1 32 19 98 11 27 1 49 18 77 10 83 1 67 17 48 10 37 1 87 16 10 9 87 2 09 67 20 16 15 23 1 18 19 14 14 80 1 33 18 07 14 3...

Page 19: ...003 0 99 0 95 FX4CNF024 0 98 0 99 FY4ANF024 0 97 1 06 FY4ANF030 0 97 1 06 CAP 2414A 0 97 1 09 CAP 2417A 0 97 1 09 CAP 3014A 0 98 1 07 CAP 3017A 0 98 1 07 CNPF 2418A 0 97 1 09 CNPH 2417A 0 97 1 06 CNPH...

Page 20: ...99 1 08 CAP 3614A 0 96 1 00 CAP 3617A 0 99 1 03 CAP 3621A 0 99 1 03 CNPF 3618A 0 99 1 03 CNPH 3017A 0 99 1 03 CNPH 3617A 0 99 1 03 CNPV 3014A 0 99 1 03 CNPV 3017A 0 99 1 03 CNPV 3617A 0 99 1 03 CNPV 3...

Page 21: ...A 0 96 1 07 CNPH 3617A 0 96 1 04 CNPH 4221A 0 97 1 06 CNPV 3617A 0 96 1 04 CNPV 3621A 0 96 1 04 CNPV 4221A 0 97 1 06 CSPH 3612A 0 96 1 04 CSPH 4212A 0 97 1 01 CAP 3614A 0 93 0 97 315 A J AV036070 CNPH...

Page 22: ...SPH 4212A 0 98 1 06 CSPH 4812A 0 99 1 07 CNPH 4221A 0 96 1 00 315 A J AV036070 CNPH 4821A 0 98 1 02 315 A J AV036070 CSPH 4212A 0 96 1 00 315 A J AV036070 CSPH 4812A 0 98 1 02 315 A J AV036070 CAP 481...

Page 23: ...1 00 1 00 FE4ANB006 1 00 1 00 FE4ANF005 1 00 1 04 FV4BNB006 1 00 1 00 FV4BNF005 1 00 1 04 FX4CN B F 048 1 00 1 04 FY4ANB060 1 00 1 08 FY4ANF048 1 00 1 16 CAP 4817A 0 98 1 06 CAP 4821A 1 00 1 08 CAP 4...

Page 24: ...48 16 4 82 56 81 46 67 5 30 53 32 45 13 5 83 49 59 43 48 6 40 45 51 41 66 7 02 62 62 50 61 84 4 37 59 65 59 65 4 81 56 86 56 86 5 31 53 91 53 91 5 84 50 70 50 70 6 42 47 12 47 12 7 05 57 62 26 62 26...

Page 25: ...5 21 52 21 52 1 55 24 88 24 88 1 64 75 525 5 64 5 19 1 21 7 65 7 03 1 27 9 76 8 90 1 34 12 02 10 68 1 40 14 49 13 19 1 48 17 31 17 31 1 58 20 37 20 37 1 70 23 77 23 77 1 84 600 5 75 5 29 1 21 7 76 7 1...

Page 26: ...07 CNPF 2418A 1 01 1 05 CNPH 2417A 1 01 1 05 CNPH 3017A 1 01 1 06 CNPV 2414A 1 01 1 05 CNPV 2417A 1 01 1 05 CNPV 3014A 1 01 1 06 CNPV 3017A 1 01 1 06 CSPH 2412A 1 01 1 05 CSPH 3012A 1 01 1 06 Heating...

Page 27: ...1 02 1 06 CNPV 3017A 1 02 1 06 CNPV 3617A 1 02 1 06 CNPV 3621A 1 02 1 06 CSPH 3012A 1 02 1 05 CSPH 3612A 1 02 1 02 CAP 3014A 0 98 1 02 315 A J AV036070 CAP 3614A 0 95 0 98 315 A J AV036070 CNPH 3017A...

Page 28: ...CSPH 4212A 1 01 1 04 CAP 3614A 0 98 1 06 315 A J AV036070 CNPH 3617A 0 97 1 05 315 A J AV036070 CNPH 4221A 0 98 1 03 315 A J AV036070 CSPH 3612A 0 97 1 01 315 A J AV036070 CSPH 4212A 0 98 1 01 315 A...

Page 29: ...3 315 A J AV036070 CSPH 4812A 0 98 1 04 315 A J AV036070 CAP 4817A 0 98 1 02 315 A J AV048090 CNPH 4221A 0 96 1 04 315 A J AV048090 CNPH 4821A 0 98 1 03 315 A J AV048090 CSPH 4212A 0 96 1 02 315 A J A...

Page 30: ...04 FY4ANB060 1 02 1 08 FY4ANF048 1 00 1 09 CAP 4817A 0 99 1 08 CAP 4821A 1 01 1 09 CAP 4824A 1 01 1 09 CAP 6021A 1 01 1 08 CAP 6024A 1 01 1 08 CNPF 4818A 0 98 1 11 CNPH 4821A 1 01 1 09 CNPH 6024A 1 01...

Page 31: ...9 51 27 12 4 18 35 83 32 67 4 38 42 51 37 75 4 59 49 79 45 31 4 83 58 34 58 34 5 06 66 67 66 67 5 35 75 53 75 53 5 68 2000 24 01 22 09 4 03 29 99 27 56 4 20 36 35 33 14 4 38 43 07 38 26 4 58 50 52 45...

Page 32: ...hase type with class B insulation and permanently lubricated bearings Shafts will be corrosion resistant Fan blades will be statically and dynamically balanced Condenser fan openings will be equipped...

Reviews: