17
A12184
5.4.1.
Hydronic Heat Application
The Evolution Connex Control supports 2 types of Hydronic Heat applications:
1. Hot water coil in combination with an FE fan coil and heat pump, or hot
water coil as sole heat source with an FE fan coil.
2. Non--zoned FE fan coil combined with radiant hot water heat.
In either application, a Hydronic Heat kit should be installed in place of an electric
heater. See FE fan coil Product Data for accessory part number. The system will
self--identify that hydronic heat has been installed during electric heater selection.
The system will treat the hot water coil as either auxiliary heat in a heat pump
application, or the sole heat source. Setup options for Hydronic Heat applications
are described in the setup section of this instruction.
5.5.
Searching for Zones (if applicable)
This function is not available with the 986T furnace.
“Zoning -- Searching” will appear on the screen to determine if any zones are
present. The screen will show Zone 1, Zone 2, etc. and indicate all zones having
either a Remote Room Sensor, or smart sensors associated with them. If the system
contains smart sensors, they must be assigned a zone number before continuing.