![Bryant DURAPAC 579F Installation, Start-Up And Service Instructions Manual Download Page 26](http://html1.mh-extra.com/html/bryant/durapac-579f/durapac-579f_installation-start-up-and-service-instructions-manual_2822196026.webp)
—
26
—
Table 18 — Fan Performance — 579F300 (High Heat Units)
LEGEND
NOTES:
1. Standard low-medium static drive range is 1066 to 1283 rpm. Alternate high-
static drive range is 1332 to 1550. Other rpms require a field-supplied drive.
2. Maximum continuous bhp is 10.2 (208/230 v) or 11.8 (460 v) and the maxi-
mum continuous watts are 9510 (208/230 v) or 11,000 (460 v). Do not adjust
motor rpm such that motor maximum bhp and/or watts is exceeded at the
maximum operating cfm.
3. Static pressure losses (i.e., EconoMi$erIV) must be added to external static
pressure before entering Fan Performance table.
4. Interpolation is permissible. Do not extrapolate.
5. Fan performance is based on wet coils, clean filters, and casing losses. See
Table 21 for accessory/FIOP static pressure information.
6. Extensive motor and drive testing on these units ensures that the full horse-
power and watts range of the motor can be utilized with confidence. Using
the fan motors up to the watts or bhp rating shown will not result in nuisance
tripping or premature motor failure. Unit warranty will not be affected.
7. Use of a field-supplied motor may affect wiring size. Contact your local
Bryant representative for details.
Table 19 — Air Quantity Limits
Table 20 — Accessory/FIOP Static Pressure*
(in. wg) — 579F180
LEGEND
FIOP —
Factory-Installed Option
*The static pressure must be added to external static pressure. The
sum and the evaporator entering-air cfm should then be used in con-
junction with the Fan Performance tables to determine blower rpm and
watts.
Table 18 — Accessory/FIOP Static Pressure*
(in. wg) — 579F216-300
LEGEND
FIOP —
Factory-Installed Option
*The static pressure must be added to external static pressure. The
sum and the evaporator entering-air cfm should then be used in con-
junction with the Fan Performance tables to determine blower rpm and
watts.
Table 22 — Perfect Humidity™ Dehumidification
Package Static Pressure Drop (in. wg)
AIRFLOW
(cfm)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.2
0.4
0.6
0.8
1.0
1.2
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
7,000
992
4.05
3,348
1051
4.44
3,668
1106
4.83
3995
1160
5.24
4331
1212
5.65
4675
1262
6.08
5026
7,500
1055
4.77
3,947
1110
5.17
4,277
1162
5.58
4615
1214
6.00
4960
1263
6.43
5312
1311
6.86
5672
8,000
1118
5.58
4,610
1170
5.99
4,950
1220
6.41
5298
1268
6.84
5653
1315
7.27
6014
1361
7.72
6382
8,500
1182
6.46
5,339
1231
6.88
5,690
1278
7.31
6047
1324
7.75
6411
1369
8.20
6782
1413
8.66
7158
9,000
1246
7.42
6,136
1292
7.86
6,498
1337
8.30
6865
1381
8.75
7239
1424
9.21
7618
1466
9.68
8003
9,500
1310
8.47
7,005
1354
8.92
7,377
1397
9.38
7754
1439
9.84
8137
1480
10.31
8525
1520
10.79
8918
10,000
1374
9.61
7,947
1416
10.07
8,329
1457
10.54
8715
1497
11.02
9107
1537
11.50
9504
—
—
—
10,500
1439
10.84
8,964
1479
11.32
9,356
1518
11.79
9752
—
—
—
—
—
—
—
—
—
11,000
1503
12.17
10,059
1542
12.65
10,460
—
—
—
—
—
—
—
—
—
—
—
—
11,250
1536
12.86
10,636
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
AIRFLOW
(cfm)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
1.6
1.8
Rpm
Bhp
Watts
Rpm
Bhp
Watts
Rpm
Bhp
Watts
7,000
1311
6.51
5385
1359
6.96
5751
1405
6.00
6124
7,500
1358
7.30
6039
1403
7.76
6412
1448
6.84
6792
8,000
1406
8.17
6767
1560
8.63
7137
1492
7.75
7524
8,500
1456
9.12
7541
1498
9.59
7929
1539
8.75
8323
9,000
1507
10.15
8393
1548
10.63
8790
—
—
—
9,500
—
—
—
—
—
—
—
—
—
10,000
—
—
—
—
—
—
—
—
—
10,500
—
—
—
—
—
—
—
—
—
11,000
—
—
—
—
—
—
—
—
—
11,250
—
—
—
—
—
—
—
—
—
Bhp
—
Brake Horsepower
FIOP
—
Factory-Installed Option
Watts —
Input Watts to Motor
UNIT
579F
MINIMUM
COOLING
CFM
MINIMUM
HEATING CFM
MAXIMUM
CFM
Low Heat
High Heat
180
4500
3800
3800
7,500
216
5400
4750
5450
9,000
240
6000
4750
5450
10,000
300
7000
4750
5450
11,250
COMPONENT
CFM
4500
5000
6000
7200
7500
EconoMi$erIV
0.04
0.05
0.07
0.09
0.10
COMPONENT
CFM
5000
6000
7200
9000
10,000
11,250
EconoMi$erIV
0.06
0.07
0.09
0.11
0.12
0.14
UNIT SIZE
579F
UNIT NOMINAL
TONS
CFM PER TON
300
400
500
180
15
.040
.071
.111
216
18
.058
.102
.160
240
20
.071
.126
.197
300
25
.111
.197
.308