SPECIFICATIONS Continued
* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26.
If other than uncoated (non-plated), 60 or 75°C (140 or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG)
is used, consult applicable tables of the NEC (ANSI/NFPA 70).
‡ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%.
** Fan motor with ball bearings required.
††
See low-ambient controller Installation Instructions for application.
N/A — Not Applicable.
NOTE:
Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.
UNIT SIZE-SERIES
048-B
060-A
Operating Weight (Lb)
295
345
ELECTRICAL
Unit Volts—Hertz—Phase
208/230—60—1
Operating Voltage Range*
187—253
Compressor—Rated Load Amps
20.5
26.9
Locked Rotor Amps
109.0
145.0
Condenser Fan Motor—Full Load Amps
1.1
1.4
Min Unit Ampacity for Wire Sizing
26.7
35.0
Min Wire Size (60°C Copper) AWG†
10
8
Min Wire Size (75°C Copper) AWG†
10
8
Max Wire Length (Ft) (60°C Copper)‡
74
89
Max Wire Length (Ft) (75°C Copper)‡
70
84
Max Branch Circuit Fuse or
Circuit Breaker Size (Amps)
40
60
COMPRESSOR & REFRIGERANT
Compressor— Type
Scroll
Temperature & Current Protection
Internal Line Break
Refrigerant—Type
Puron® (R-410A)
Amount (Lb)
12.00
15.00
CONDENSER COIL & FAN
Coil Face Area (Sq Ft)
18.3
24.5
Fins per In.—Rows—Circuits
20—2—4
20—2—6
Fan Motor—HP (PSC) & RPM
1/5 & 825
1/5 & 825
Volts—Hertz—Phase
208/230—60—1
Condenser Airflow (CFM)
2800
3800
OPTIONAL EQUIPMENT
Support Feet
KSASF0101AAA
Coastal Filter
KAACF0801MED
KAACF0901LRG
Time Delay Relay
KAATD0101TDR
Cycle Protector
KSACY0101AAA
Crankcase Heater
KAACH1201AAA
Start Assist—Capacitor/Relay Type
KSAHS1501AAA
KSAHS1601AAA
Start Assist—PTC Type
KAACS0201PTC
TXV (Hard Shutoff)
KSATX0401PUR
KSATX0501PUR
Piston Body
KSAPX0101PIS
Filter Drier (Suction Line)
KH45LG141 (RCD)
Evaporator Freeze Thermostat††
KAAFT0101AAA
Liquid-Line Solenoid Valve
KAALS0201LLS
Winter Start Control††
KAAWS0201AAA
Low-Ambient Pressure Switch
KSALA0301410
MotorMaster®—Low-Ambient Controller**
KSALA0401AAA
Ball Bearing Fan Motor
HC38GE231 (RCD)
HC38GE232 (RCD)
Thermidistat™ Control—
Programmable Thermostat with Humidity Control
TSTATBBPRH01-B
Thermostat—Auto Changeover, 7-Day Programmable,
°F/°C, 1-Stage Heat, 1-Stage Cool
TSTATBBPAC01-B
Thermostat—Auto Changeover, Non-Programmable,
°F/°C, 1-Stage Heat, 1-Stage Cool
TSTATBBNAC01-B
Thermostat—Manual Changeover, 5-2 Day
Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
TSTATBBSAC01
Builder’s Thermostat—Manual Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
TSTATBBBAC01-B
Outdoor Air Temperature Sensor
TSTATXXSEN01-B
Backplate for Non-Programmable Thermostat
TSTATXXNBP01
Backplate for Programmable Thermostat
TSTATXXPBP01
Backplate for Builder’s Thermostat
TSTATXXBBP01
Backplate for Standard Thermostat
TSTATXXSBP01
Thermostat Conversion Kit (4 to 5 wire)—10 Pack
TSTATXXCNV10
Evolution Controls
See chart