—23—
* Tested combination.
† In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
‡ TXV must be Puron® compatible and hard shutoff type.
EER
— Energy Efficiency Ratio
SEER
— Seasonal Energy Efficiency Ratio
TDR
— Time-Delay Relay
TXV
— Thermostatic Expansion Valve
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for electric air conditioners. Ratings for other com-
binations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
060-A
*CD5PX060
58,000
TXV
—
14.00
—
—
12.00
CC5A/CD5AA060
56,000
NONE
—
—
13.50
—
11.55
CC5A/CD5AW060
57,000
NONE
—
—
13.50
—
11.80
CE3AA060
58,000
NONE
—
—
13.50
—
11.95
CK3BA060
57,500
NONE
—
—
13.50
—
11.85
CK5A/CK5BA060
57,500
NONE
—
—
13.50
—
11.85
CK5A/CK5BT060
57,500
NONE
—
—
13.50
—
11.85
CK5A/CK5BX060
58,000
NONE
—
—
13.50
—
12.05
CK5PA060
57,500
TXV
—
13.50
—
—
11.85
CK5PT060
57,500
TXV
—
13.50
—
—
11.85
CK5PX060
58,000
TXV
—
13.50
—
—
12.05
F(A,B)4BN(F,B,C)060
58,000
TDR
—
—
—
13.50
11.60
FB4BNB070
59,000
TDR
—
—
—
14.00
12.00
FC4CN(F,B)060
58,000
TDR&TXV
13.50
—
—
—
11.60
FC4CNB070
59,000
TDR&TXV
14.00
—
—
—
12.00
FE4ANB006
59,000
TDR&TXV
15.00
—
—
—
12.80
FG3AAA060
57,000
NONE
—
—
13.50
—
11.65
FK4DNB006
59,000
TDR&TXV
15.00
—
—
—
12.80
FV4BNB006
59,000
TDR&TXV
15.00
—
—
—
12.80
FX4BNB060
58,500
TDR&TXV
14.00
—
—
—
12.00
COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
56,000
TDR
—
—
—
13.50
11.45
CD5PX060
58,000
TDR&TXV
14.00
—
—
—
11.90
CE3AA060
58,000
TDR
—
—
—
14.00
11.95
CK3BA060
57,500
TDR
—
—
—
14.00
11.90
CK5A/CK5BA060
57,500
TDR
—
—
—
14.00
11.90
CK5A/CK5BT060
57,500
TDR
—
—
—
14.00
11.90
CK5A/CK5BX060
58,000
TDR
—
—
—
14.00
12.05
CK5PA060
57,500
TDR&TXV
14.00
—
—
—
11.90
CK5PT060
57,500
TDR&TXV
14.00
—
—
—
11.90
CK5PX060
58,000
TDR&TXV
14.00
—
—
—
12.05
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
56,000
TDR
—
—
—
14.00
11.80
CD5PX060
58,000
TDR&TXV
14.50
—
—
—
12.30
CE3AA060
58,000
TDR
—
—
—
14.00
12.25
CK3BA060
57,500
TDR
—
—
—
14.00
12.25
CK5A/CK5BA060
57,500
TDR
—
—
—
14.00
12.25
CK5A/CK5BT060
57,500
TDR
—
—
—
14.00
12.25
CK5A/CK5BX060
58,000
TDR
—
—
—
14.00
12.40
CK5PA060
57,500
TDR&TXV
14.00
—
—
—
12.25
CK5PT060
57,500
TDR&TXV
14.00
—
—
—
12.25
CK5PX060
58,000
TDR&TXV
14.00
—
—
—
12.40
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
56,000
TDR
—
—
—
14.00
11.95
CD5PX060
58,000
TDR&TXV
14.50
—
—
12.40
CE3AA060
58,000
TDR
—
—
—
14.00
12.40
CK3BA060
57,500
TDR
—
—
—
14.00
12.35
CK5A/CK5BA060
57,500
TDR
—
—
—
14.00
12.35
CK5A/CK5BT060
57,500
TDR
—
—
—
14.00
12.35
CK5A/CK5BX060
58,000
TDR
—
—
—
14.00
12.55
CK5PA060
57,500
TDR&TXV
14.00
—
—
—
12.35
CK5PT060
57,500
TDR&TXV
14.00
—
—
—
12.35
CK5PX060
58,000
TDR&TXV
14.00
—
—
—
12.55
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CK5A/CK5BX060
58,000
TDR
—
—
—
14.00
11.90
CK5PX060
58,000
TDR&TXV
14.00
—
—
—
11.90
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CK3BA060
57,500
TDR
—
—
—
14.00
11.85
CK5A/CK5BA060
57,500
TDR
—
—
—
14.00
11.85
CK5A/CK5BT060
57,500
TDR
—
—
—
14.00
11.85
CK5A/CK5BX060
58,000
TDR
—
—
—
14.00
12.00
CK5PA060
57,500
TDR&TXV
14.00
—
—
—
11.85
CK5PT060
57,500
TDR&TXV
14.00
—
—
—
11.85
CK5PX060
58,000
TDR&TXV
14.00
—
—
—
12.00
UNIT
SIZE-SERIES
INDOOR
MODEL
Cooling
Capacity
Factory
Enhance
SEER
EER
Standard
Rating
Bryant Gas
Furnace or
Accessory
TDR†
Bryant Gas Furnace
or Accessory TDR†
and Puron TXV‡
Accessory
Puron TXV‡
COMBINATION RATINGS continued