background image

2

SAP ORDERING

NO.

CASING

DIMENSIONS

(IN.)

RATED HEATING OUTPUT†

(BTUH)

HEATING AIRFLOW

COOLING

CFM @ 0.5

ESP

(in. W.C.)

MOTOR HP -

SPEED

(VARIABLE

SPEED)

H

D

W

High

Low

AFUE

CFM‡ (High

Heating

CFM (Low

Heating)

High Heating

ESP

(in. W.C.)

926TA30040V14

35

29.5

14.2

39,000

25,000

96.5%

815

660

0.10

905

1/2

926TA36040V17

35

29.5

17.5

39,000

25,000

96.0%

860

660

0.10

1065

1/2

926TA36060V14

35

29.5

14.2

58,000

38,000

95.0%

1120

910

0.12

1065

1/2

926TA42060V17

35

29.5

17.5

58,000

38,000

96.3%

1135

860

0.12

1475

3/4

926TA48080V17

35

29.5

17.5

78,000

50,000

96.2%

1505

1160

0.15

1610

3/4

926TA60080V21

35

29.5

21.0

78,000

51,000

96.5%

1555

1200

0.15

2005

1

926TA60100V21

35

29.5

21.0

97,000

63,000

96.1%

1865

1435

0.20

2005

1

926TA66120V24

35

29.5

24.0

117,000

76,000

96.5%

2375

1675

0.20

2115

1

{

Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate.

Minimum heat CFM when low---heat rise adjustment switch (SW 1---3) and comfort/efficiency adjustment switch (SW1---4) on control center are OFF.

ESP --- External Static Pressure

FEATURES AND BENEFITS

Perfect Heat

R

Technology

— This feature with Adaptive Control

is a proprietary function that promotes homeowner comfort

through two stages of heating. This Bryant furnace offers a
patented algorithm that continually monitors and adjusts furnace

operation by looking at both current and past conditions to

determine the most effective stage of heating and the amount of
time to run each stage, every cycle.

SmartEvap

t

Technology

— When paired with a compatible

thermostat, this dehumidification feature overrides the cooling

blower off-delay when there is a call for dehumidification. By

deactivating the blower off-delay, SmartEvap technology prevents
condensate that remains on the coil after a dehumidification cycle

from re-humidifying throughout the home. This results in reduced
humidity and a more comfortable indoor environment for the

homeowner.
Unlike competitive systems, SmartEvap technology only overrides
the cooling blower off delay when humidity control is needed.

Once humidity is back in control, SmartEvap re-enables the
energy-saving cooling blower off-delay.

Fan On Plus

t

Technology

— Sometimes the constant fan setting

on a standard furnace system can actually reduce homeowner

comfort by providing too much or too little air! Fan On Plus

technology improves comfort all year long by allowing the
homeowner to select the continuous fan speed of their choice using

a compatible thermostat.

HYBRID HEAT

R

Dual Fuel system

— This system can provide

more control over your monthly energy bills by automatically

selecting the most economical method of heating. With HYBRID
HEAT, our system automatically switches between the gas furnace

and the electric heat pump as outside temperatures change to
maintain greater efficiency and comfort than with any traditional

single-source heating system. The heat pump also delivers

high-efficiency cooling in the summer.

Power Heat

t

Igniter

— Bryant’s unique SiN igniter is not only

physically robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage

regulators as do other brands. This unique feature further enhances
the gas furnace reliability and continues Bryant’s tradition of

technology leadership and innovation in providing a reliable and

durable product.

Full-Featured, Variable Speed Motors

— Our variable--speed

ECM (Electronically Commutated Motor) optimizes comfort levels
in the home year round; features such as passive/active

dehumidification, ramping profiles, and quiet operation. They can

provide cooling match enhancements to increase the effective
SEER of select Bryant air conditioner or heat pump system. This

motor does not report back RPM and static pressure to enable static
pressure reporting to the UI or zoning system, which is required for

zoning, active filter monitoring and system static pressure

reporting.

Reliable Heat Exchanger Design

— The aluminized steel, clam

shell primary heat exchanger was re--engineered to achieve greater

efficiency out of a smaller size. The first two passes of the heat
exchanger are based on the current 80% product, a design with

more than ten years of field-proven performance and success.

These innovations, paired with the continuation of a crimped,
no-weld seam create an efficient, robust design for this essential

component.
The condensing heat exchanger, a stainless steel fin and tube

design, is positioned in the furnace to extract additional heat.

Stainless steel coupling box componentry between heat exchangers
has exceptional corrosion resistance in both natural gas and

propane applications.

Optional Media Filter Cabinet

— Enhanced indoor air quality in

the home is made easier with our media filter cabinet When

installed as a part of the system, this cabinet allows for easy and
convenient addition of a Bryant high efficiency air filter.

4-Way Multipoise Design

— One model for all applications –

there is no need to stock special downflow or horizontal models

when one unit will do it all. The new heat exchanger design allows
these units to achieve the certified AFUE in all positions.

Direct or Single-pipe Venting, or Optional Ventilated

Combustion Air

— This furnace can be installed as a 2-pipe

(Direct Vent) furnace, in an optional ventilated combustion air

application, or in single-pipe, non-direct vent applications. This
provides added flexibility to meet diverse installation needs.

Sealed Combustion System

— This furnace brings in combustion

air from outside the furnace, which results in especially quiet
operation. By sealing the entire combustion vestibule, the entire

furnace can be made quieter, not just the burners.

Insulated Casing

— Foil-faced insulation in heat exchanger

section of the casing minimizes heat loss. The acoustical insulation

in the blower compartment reduces air and motor noise for quiet
operation.

Monoport Burners

— The burners are specially designed and

finely tuned for smooth, quiet combustion and economical

operation.

Bottom Closure

— Factory--installed for side return; easily

removable for bottom return. The multi-use bottom closure can

also serve for roll-out protection in horizontal applications, and act
as the bottom closure for the optional return air base accessory.

Certifications

— This furnace is CSA (AGA and CGA) design

certified for use with natural and propane gases. The furnace is

factory--shipped for use with natural gas. A CSA listed gas

conversion kit is required to convert furnace for use with propane
gas. The efficiency is AHRI efficiency rating certified. This furnace

meets California Air Quality Management District emission
requirements.

926T

A

Summary of Contents for 926TA

Page 1: ...t Surface Igniter S SmartEvap technology helps control humidity levels in the home when used with a compatible humidity control system S FanOn Plus technology allows control of continuous fan speed fr...

Page 2: ...and continues Bryant s tradition of technology leadership and innovation in providing a reliable and durable product Full Featured Variable Speed Motors Our variable speed ECM Electronically Commutat...

Page 3: ...U 120 120 000 BTU 140 140 000 BTU Not all familes have these models 0 90 AFUE 2 92 AFUE 3 93 AFUE 5 95 AFUE 6 96 AFUE 7 97 AFUE Example of a Model Number A14367 FURNACE COMPONENTS RATING PLATE NOT SHO...

Page 4: ...peed Selections Variable PWM Blower Wheel Dia x Width in 11 x 7 11 x 8 11 x 7 11 x 8 11 x 8 11 x 10 11 x 10 11 x 11 Air Filtration System Optional Media Cabinet Field Supplied Filter Filter Used for C...

Page 5: ...as Orifice Kit 46 Nat Gas LH32DB208 D D D D D D D D Gas Orifice Kit 47 Nat Gas LH32DB078 D D D D D D D D Gas Orifice Kit 48 Nat Gas LH32DB076 D D D D D D D D Gas Orifice Kit 54 LP LH32DB203 D D D D D...

Page 6: ...ON OFF 770 725 685 640 600 560 515 480 See note 4 OFF ON ON 945 910 875 835 800 770 735 695 665 635 ON OFF OFF 1140 1105 1075 1040 1005 970 930 885 835 790 ON OFF ON 1250 1210 1165 1115 1065 1015 965...

Page 7: ...770 720 660 620 585 ON OFF OFF 1175 1140 1090 1060 1025 980 940 905 855 815 ON OFF ON 1325 1280 1245 1210 1180 1140 1105 1070 1025 990 ON ON OFF 1545 1515 1480 1445 1410 1380 1350 1315 1245 1175 ON O...

Page 8: ...1890 1750 1645 1550 Clg SW2 Maximum Clg Airflow 2 note 8 2375 2300 2205 2115 2010 1890 1750 1645 1550 Heating SW1 High Heat Airflow 3 note 8 2375 2300 2205 2115 2010 1890 1750 1645 1550 Low Heat Airfl...

Page 9: ...2 NA NA 60 000 23 7 0 119 36 3 210 64 0 235 71 6 NA 80 000 15 4 6 59 18 0 155 47 2 210 64 0 232 70 7 100 000 NA 19 5 8 98 29 9 211 64 3 236 71 9 120 000 NA NA 8 2 4 86 26 2 224 68 3 140 000 4 NA NA NA...

Page 10: ...ent Vent Length TEVL 112 ft Add all of the above lines Maximum Equivalent Vent Length MEVL 127 ft For 2 pipe from Table 1 Is TEVL less than MEVL YES Therefore 2 pipe may be used Example 2 A direct ven...

Page 11: ...9 8 63 19 2 8001 to 9000 2438 to 2743 40 000 10 3 0 121 36 9 130 39 6 NA NA 60 000 7 2 1 82 25 0 152 46 3 168 51 2 NA 80 000 NA 35 10 7 111 33 8 148 45 1 156 47 5 100 000 NA NA 67 20 4 157 47 9 170 51...

Page 12: ...44 8 0 20 Ft 20 0 32 0 30 0 22 0 11 0 20 0 70 0 104 0 87 0 67 0 20 0 70 0 124 0 104 0 82 0 M 6 1 9 8 9 1 6 7 3 4 6 1 21 3 31 7 26 5 20 4 6 1 21 3 37 8 31 7 25 0 20 30 Ft 20 0 17 0 14 0 6 0 0 0 20 0 7...

Page 13: ...PLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service 24 in 610 mm All Sid...

Page 14: ...5 8 600 2 24 1 2 622 Furnace with or without Cased Coil Assembly or Coil Box 22 1 8 562 19 483 23 3 4 603 20 5 8 600 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the...

Page 15: ...FIELD SUPPLIED DISCONNECT AUXILIARY J BOX 24 V TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 1 NOTE 2 FIELD SUPPLIED DISCONNECT CONDENSING UNIT TWO WIRE FURNACE C O N T R O L R G COM W C R G Y...

Page 16: ...IMENSIONS IN INCH MM 22 2 7 8 7 8 22 2 POWER CONN AIR FLOW SEE NOTE 3 NOTES 1 Doors may vary by model 2 Minimum return air openings at furnace based on metal duct If flex duct is used see flex duct ma...

Page 17: ...Casing Casing shall be of 030 in thickness minimum pre painted steel Draft Inducer Motor Draft inducer motor shall be two speed PSC design Primary Heat Exchangers Primary heat exchangers shall be 3 P...

Page 18: ...e or change at any time specifications or designs without notice and without incurring obligations E2014 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Edition Date 09 14 Re...

Reviews: