30
9. Set Airflow for Continuous Fan
/
Low Speed Cooling
Airflow The ECM blower motor can be adjusted for
continuous fan speeds different than heating or cooling fan
speed. See Table 11 -- Air Delivery -- CFM (With Filter).
Select the required continuous fan airflow from Fig. 42.
The continuous fan speed is also the switch setting for low
speed cooling when furnace is used with a 2--speed
cooling unit. Adjust the continuous fan CFM to match the
airflow required for low speed cooling. Select the required
airflow from Fig. 42. For airflow at 400 CFM per ton, turn
Setup SW1--5 ON (See Fig. 42) The airflow selected for
low speed cooling will also be the airflow used for
continuous fan.
The continuous fan speed can be further adjusted at the
thermostat using the “Comfort Fan” select function.
Changing the continuous fan speed at the thermostat
DOES NOT change the low speed cooling airflow
selected at the control board.
Table 11 – Air Delivery -- CFM (With Filter)
(SW1---5 and SW4---3 set to OFF, except as indicated. See notes 1 and 2)
Size:
36040C17
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches
SW2---3
SW2---2
SW2---1
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
1275 1310 1305 1315 1310 1305 1305 1295 1290 1270
CF Switches
SW3---3
SW3---2
SW3---1
Low---Clg Default:
OFF
OFF
OFF
1275 1310 1305 1315 1310 1305 1305 1295 1290 1270
Cooling Airflow
(SW2)
Low---Cooling
Airflow (SW3)
OFF
OFF
ON
530
545
545
535
505
495
485
See Note 4
OFF
ON
OFF
715
705
730
730
735
735
740
725
720
695
OFF
ON
ON
870
910
925
925
935
935
925
915
910
900
ON
OFF
OFF
1100 1090 1080 1110 1120 1120 1110 1110 1100 1095
ON
OFF
ON
1275 1310 1305 1315 1310 1305 1305 1295 1290 1270
ON
ON
OFF
1445 1480 1480 1480 1475 1455 1415 1375 1335 1295
ON
ON
ON
1445 1480 1480 1480 1475 1455 1415 1375 1335 1295
Maximum Clg Airflow
2
1635 1605 1565 1525 1490 1455 1415 1375 1335 1295
CF Switches
SW3---3
SW3---2
SW3---1
Cont. Fan Default:
OFF
OFF
OFF
530
545
545
535
505
495
485
See Note 4
Continuous Fan
Airflow
(SW3)
OFF
OFF
ON
530
545
545
535
505
495
485
See Note 4
OFF
ON
OFF
715
705
730
730
735
735
740
725
720
695
OFF
ON
ON
870
910
925
925
935
935
925
915
910
900
ON
OFF
OFF
1100 1090 1080 1110 1120 1120 1110 1110 1100 1095
ON
OFF
ON
1100 1090 1080 1110 1120 1120 1110 1110 1100 1095
ON
ON
OFF
1100 1090 1080 1110 1120 1120 1110 1110 1100 1095
ON
ON
ON
1100 1090 1080 1110 1120 1120 1110 1110 1100 1095
Heating (SW1)
Heating Airflow
3
760
765
790
790
800
800
800
790
775
755
Size:
48060C17
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches
SW2---3
SW2---2
SW2---1
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
1460 1475 1500 1500 1480 1440 1395 1355 1310 1255
CF Switches
SW3---3
SW3---2
SW3---1
Low---Clg Default:
OFF
OFF
OFF
540
565
555
555
535
See Note 4
Cooling Airflow
(SW2)
Low---Cooling
Airflow (SW3)
OFF
OFF
ON
540
565
555
555
535
See Note 4
OFF
ON
OFF
715
735
745
760
765
See Note 4
OFF
ON
ON
865
910
935
950
965
955
950
955
955
945
ON
OFF
OFF
1120 1125 1130 1145 1160 1165 1165 1160 1150 1150
ON
OFF
ON
1275 1295 1315 1335 1340 1345 1340 1335 1310 1255
ON
ON
OFF
1460 1475 1500 1500 1480 1440 1395 1355 1310 1255
ON
ON
ON
1460 1475 1500 1500 1480 1440 1395 1355 1310 1255
Maximum Clg Airflow
2
1620 1595 1565 1525 1480 1440 1395 1355 1310 1255
CF Switches
SW3---3
SW3---2
SW3---1
Cont. Fan Default:
OFF
OFF
OFF
540
565
555
555
535
See Note 4
Continuous Fan
Airflow
(SW3)
OFF
OFF
ON
540
565
555
555
535
See Note 4
OFF
ON
OFF
715
735
745
760
765
See Note 4
OFF
ON
ON
865
910
935
950
965
955
950
955
955
945
ON
OFF
OFF
1120 1125 1130 1145 1160 1165 1165 1160 1150 1150
ON
OFF
ON
1275 1295 1315 1335 1340 1345 1340 1335 1310 1255
ON
ON
OFF
1460 1475 1500 1500 1480 1440 1395 1355 1310 1255
ON
ON
ON
1460 1475 1500 1500 1480 1440 1395 1355 1310 1255
Heating (SW1)
Heating Airflow
3
960
995
1015 1020 1030 1050 1055 1060 1055 1045