![Bryant 594D User Manual Download Page 11](http://html1.mh-extra.com/html/bryant/594d/594d_user-manual_2822151011.webp)
—11—
COMBINATION RATINGS Continued
* Tested Combination
† In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the 394HAD.
‡ Based on computer simulation. TXV must be hard shutoff type.
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other
combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Minimum outdoor operating ambient in cooling mode is 55°F (12.8°C), maximum 125°F (51.7°C).
UNIT
SIZE-SERIES
INDOOR
MODEL
TOT. CAP.
BTUH
FACTORY
SUPPLIED
ENHANCE-
MENT
SEER
EERA
STANDARD
RATING
BRYANT GAS
FURNACE OR
ACCESSORY
TDR†
ACCESSORY
TXV‡
048-E/F
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
CC5A/CD5AA060
46,500
TDR
11.50
—
11.50
10.15
CC5A/CD5AW048
46,000
TDR
11.20
—
11.20
10.05
CC5A/CD5AW060
47,000
TDR
12.00
—
12.00
10.45
CK3BA060
46,500
TDR
11.50
—
11.50
10.35
CK5A/CK5BA060
46,500
TDR
11.50
—
11.50
10.35
CK5A/CK5BW048
46,000
TDR
11.20
—
11.20
10.10
CK5A/CK5BX060
47,000
TDR
12.00
—
12.00
10.60
COILS + 355MAV042080 VARIABLE SPEED FURNACE
CD5AA048
46,000
TDR
11.00
—
11.00
9.70
CK3BA048
46,000
TDR
11.00
—
11.00
9.75
CK5A/CK5BA048
46,000
TDR
11.00
—
11.00
9.75
COILS + 355MAV060080 VARIABLE SPEED FURNACE
CC5A/CD5AA060
46,000
TDR
11.00
—
11.00
9.70
CC5A/CD5AW060
47,000
TDR
11.20
—
11.20
9.95
CD5AA048
46,000
TDR
11.00
—
11.00
9.60
CK3BA048
46,000
TDR
11.00
—
11.00
9.70
CK5A/CK5BA060
46,500
TDR
11.00
—
11.00
9.90
CK5A/CK5BX060
47,000
TDR
11.20
—
11.20
10.15
CK5A/CK5BA048
46,000
TDR
11.00
—
11.00
9.70
COILS + 355MAV060100 VARIABLE SPEED FURNACE
CC5A/CD5AA060
46,000
TDR
11.20
—
11.20
9.95
CC5A/CD5AC048
45,000
TDR
11.00
—
11.00
9.70
CC5A/CD5AW060
47,000
TDR
11.80
—
11.80
10.20
CD5AA048
46,000
TDR
11.00
—
11.00
9.90
CK3BA048
46,000
TDR
11.00
—
11.00
9.95
CK3BA060
46,500
TDR
11.20
—
11.20
10.15
CK5A/CK5BA048
46,000
TDR
11.00
—
11.00
9.95
CK5A/CK5BA060
46,000
TDR
11.20
—
11.20
10.40
CK5A/CK5BX060
47,000
TDR
11.80
—
11.80
10.40
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CC5A/CD5AA060
46,000
TDR
11.20
—
11.20
9.95
CC5A/CD5AW048
46,000
TDR
11.20
—
11.20
9.90
CC5A/CD5AW060
47,000
TDR
11.80
—
11.80
10.25
CK3BA060
46,500
TDR
11.20
—
11.20
10.20
CK5A/CK5BA060
46,000
TDR
11.20
—
11.20
10.20
CK5A/CK5BW048
46,000
TDR
11.20
—
11.20
9.95
CK5A/CK5BX060
47,000
TDR
11.80
—
11.80
10.45
060-E
CC5A/CD5AW060*
56,500
NONE
10.80
11.00
11.00
9.70
CC5A/CD5AA060
54,500
NONE
10.60
10.80
10.80
9.55
CE3AA060
56,500
NONE
10.80
11.00
11.00
9.80
CK5A/CK5BA060
54,500
NONE
10.60
10.80
10.80
9.55
CK5A/CK5BX060
56,500
NONE
10.80
11.00
11.00
9.70
F(A,B)4AN(F,B,C)060
57,000
TDR
10.80
—
10.80
9.40
FB4ANB070
57,500
TDR
11.00
—
11.00
9.80
FC4BNB070
57,500
TDR & TXV
11.00
—
—
9.80
FC4BN(F,B)060
57,000
TDR & TXV
10.80
—
—
9.40
FG3AAA060
56,000
NONE
10.80
11.00
11.00
9.65
FK4CNB006
57,500
TDR & TXV
12.00
—
—
10.30
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
CC5A/CD5AW060
56,500
TDR
11.80
—
11.80
10.30
CK5A/CK5BW060
56,500
TDR
11.80
—
11.80
10.30