177
BASE UNIT DIMENSIONS — 579F180,216
NO
TES:
1.
Re
fe
r
to
pr
in
t fo
r r
o
o
f
cu
rb
a
cce
sso
ry
dim
e
n
s
io
ns
.
2
.
Dimen
s
io
n
s in
(
)
are
in
mill
imeters.
3.
C
e
nt
er
of
G
rav
it
y.
4.
D
ir
e
c
ti
on
of
a
ir
fl
o
w
.
5
.
Duct
work
to
be at
ta
ched
t
o
accesso
ry
ro
of curb
on
ly
.
6
.
Mini
mum cle
a
rance:
•R
e
a
r:
7
′
-0
″
(2
134) f
o
r coil removal
. This dimensio
n
can
b
e
r
educed
t
o
4
′
-0
″
(1
219)
if
co
ndit
ions permi
t coil removal f
rom th
e
to
p
.
•4
′
-0
″
(1
219)
t
o
combust
ible
sur
faces,
all fo
ur sides (includ
e
s
b
e
tw
e
e
n
unit
s).
•
L
ef
t side:
4
′
-0
″
(121
9) fo
r
p
rope
r
con
denser
coil air
flo
w
.
•
F
ront
: 4
′
-0
″
(1219
) for
cont
rol
bo
x access.
•
R
ight
side
:
4
′
-0
″
(1219
)
fo
r pro
per ope
rat
ion of
d
a
mper an
d
p
o
wer
e
x
h
aust
if
so
eq
uipp
ed.
•T
o
p
: 6
′
-0
″
(182
9) to assure
pr
oper
cond
enser f
an oper
ati
on.
•
B
ot
tom:
14
″
(35
6
) to
combu
s
ti
ble
sur
faces (when
no
t using
curb
).
•
C
o
n
tr
ol box sid
e
:
3
′
-0
″
(914
) to un
groun
ded surf
aces, no
n-combust
ible
.
•
C
o
n
tr
ol box side:
3
′
-6
″
(10
67) t
o
blo
c
k or con
c
re
te
w
a
lls, or
oth
e
r
g
roun
ded surf
aces.
•
L
ocal co
des or jurisdict
ion may prevai
l.
7
.
Wit
h
t
he
exce
pt
ion o
f cle
a
rance
fo
r t
he con
denser
co
il an
d t
he d
a
mper
/
p
o
wer exha
ust as st
at
ed in Not
e
#6,
a removabl
e fen
c
e
o
r barr
ica
de
requi
res n
o
cle
a
ran
c
e
.
8.
D
im
e
n
s
ion
s a
re f
rom
o
u
ts
ide
o
f co
rn
er
p
o
s
t.
A
llo
w
0
′
-
5
/
16
″
(8)
on ea
ch
side
fo
r
top cover drip
ed
ge.
9
.
Se
e
drawing
5
0
TJ5
0035
2 f
o
r service
opt
ion
de
ta
ils.
UNIT
579
F
STD UNIT
WEI
G
HT
ECONO
M
IZER
WEI
G
HT
CORNER
A
CORNER
B
COR
N
E
R
C
CORNER
D
DIM
A
D
IM
B
D
IM
C
Lb
Kg
Lb
Kg
L
b
Kg
Lb
Kg
Lb
Kg
L
b
Kg
ft
-i
n.
mm
ft
-i
n.
m
m
ft-in.
m
m
18
0
1650
748
90
41
423
192
38
6
175
403
18
3
438
199
3
-5
1
041
3-5
1041
1
-10
559
21
6
1800
816
90
41
432
196
41
0
186
461
20
9
472
214
3
-3
991
3-7
1092
1-8
508
a48-7338
579
F18
0
-300
Summary of Contents for 581A
Page 30: ...30 BASE UNIT DIMENSIONS 580F036 072 a48 8195 580F036 151 ...
Page 31: ...31 BASE UNIT DIMENSIONS 580F073 a48 8196 580F036 151 ...
Page 32: ...32 BASE UNIT DIMENSIONS 580F090 120 150 a48 8197 580F036 151 ...
Page 33: ...33 BASE UNIT DIMENSIONS 580F091 103 121 151 a48 8198 580F036 151 ...
Page 91: ...91 BASE UNIT DIMENSIONS 581B036 072 a48 8199 581B036 150 ...
Page 93: ...93 ACCESSORY DIMENSIONS 581B036 072 a48 8201 581B036 150 ...
Page 94: ...94 ACCESSORY DIMENSIONS 581B090 150 a48 8202 581B036 150 ...
Page 150: ...150 BASE UNIT DIMENSIONS 581C024 060 581C024 060 ...
Page 198: ...198 TYPICAL WIRING SCHEMATICS 579F 579F240 208 230 V Shown a48 7929 ...
Page 205: ...205 BASE UNIT DIMENSIONS 580F180 210 a48 8203 580F180 300 ...
Page 206: ...206 BASE UNIT DIMENSIONS 580F240 a48 8204 ...
Page 207: ...207 BASE UNIT DIMENSIONS 580F300 a48 8205 580F180 300 ...
Page 209: ...209 ACCESSORY DIMENSIONS 580F300 Vertical Roof Curbs 580F300 a48 7456 580F180 300 ...
Page 233: ...233 BASE UNIT DIMENSIONS 581A210 300 a48 8206 581A155 180 ...
Page 237: ...237 ACCESSORY DIMENSIONS 581A210 300 a48 8234 581A155 180 ...
Page 280: ...280 TYPICAL PIPING AND WIRING 581A 581A155 Shown LEGEND NEC National Electrical Code b48 1258 ...
Page 297: ...297 ...