background image

A94328

SERVICE TRAINING

Packaged Service Training programs are an excellent way to increase your 
knowledge of the equipment discussed in this manual, including:

• Unit Familiarization

• Maintenance

• Installation Overview

• Operating Sequence

A large selection of product, theory, and skills programs is available, using popular 
video-based formats and materials.  All include video and/or slides, plus companion 
book.

Classroom Service Training plus "hands-on" the products in our labs can mean 
increased confidence that really pays dividends in faster troubleshooting, fewer 
callbacks.  Course descriptions and schedules are in our catalog.

CALL  FOR  FREE  CATALOG  1-800-962-9212

[  ] Packaged Service Training

[  ] Classroom Service Training

© 2001 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231

—12—

Printed in U.S.A.

369r701

Catalog No. 5336-907

Summary of Contents for 369RAN

Page 1: ...are intended to be used by qualified personnel who have been trained in installing this type of furnace Installation of this furnace by an unqualified person may lead to equipment damage and or a haz...

Page 2: ...quate duct work and connection to a properly sized vent The air handling capacity of this furnace is designed for cooling airflow Refer to Table 12 for expected airflows at various external duct stati...

Page 3: ...is will cause condensation in heat exchanger and possible failure of heat exchanger which could lead to a fire hazard and or a hazardous condition which may lead to bodily harm Heat exchanger failure...

Page 4: ...ctrical and fuel lines and at other openings If combustion and ventilation air must be supplied to an uncon fined space from outside an opening with a FREE AREA of not less than 1 sq in per 1000 Btuh...

Page 5: ...CONNECTED TO FLUES HAVING SUFFICIENT DRAFT AT ALL TIMES TO ENSURE SAFE AND PROPER OPERATION OF APPLIANCE For additional venting information refer to ANSI NFPA 211 Chimney Fireplaces Vents and Solid Fu...

Page 6: ...have an uninter rupted or unbroken electrical ground to minimize per sonal injury if an electrical fault should occur A green ground screw is provided in control box for this connec tion 115 V WIRING...

Page 7: ...ace of damper vertical See instructions included with damper The draft regu lator should be adjusted after furnace has been firing for at least 5 minutes and set between 0 025 and 0 035 in wc See Tabl...

Page 8: ...Fig 3 Wiring Diagram 036105 A00420 8...

Page 9: ...Fig 4 Wiring Diagram 060120 A00419 9...

Page 10: ...STANT BLOWER SWITCH This furnace is equipped with a constant low speed blower option Whenever room thermostat is not calling for heating or cooling blower runs on low speed in order to provide air cir...

Page 11: ...e flue collar panel located in front part of furnace 4 Remove baffle from secondary heat exchanger 5 Disconnect oil line and remove oil burner from furnace 6 Open two cleanout doors located in upper p...

Page 12: ...video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products in our labs can mean increased confidence that really pays d...