background image

Chemical 

Water Treatment

All boilers require proper care and maintenance to
assure optimal performance. In particular, steam boilers
will operate more efficiently if serviced by a surface or
bottom blowdown system. Bryan Steam can provide
these systems in either manual or automatic designs. A
regular blowdown procedure to remove accumulated
sludge will extend the life and performance of your boil-
er. A Bryan system will assure that your boiler has regu-
lar blowdown on a preset schedule.

All boilers require proper
care and maintenance to
maintain optimal per-
formance. In particular,
steam boilers will operate
more efficiently if serv-
iced properly by chemical
feed systems, water
meters, and chemical
shot feeders. Bryan
Steam can provide all of
these enhanced boiler-
operating items.

Steam Exhaust Head

Size ranges from 1" - 24"

Overflow Trap

Size ranges from 2" - 6"

Automatic Blowdown System

The Bryan exhaust head
gives three levels of pro-
tection against oil and
water pollution: first, an
expansion chamber; sec-
ond, an impingement
cone; and third, a catch
trough and drain. What
one misses, another gets,
resulting in oil-free, water-
free exhaust steam.

Overflow traps are primarily
used on pressurized deaer-
ators in order to keep the
pressure in the deaerator,
but to also overflow water
to a drain if the deaerator
becomes flooded. Bryan
overflow trap bodies are
constructed of cast iron.
Inside the body, a double-seated brass valve is 
automatically operated by a stainless steel ball float.

Chemical Feed System

30 - 100 gallon capacity
Pumps 1.8 - 6 GPH

 of steam and water

7

Shot Feeder

¾ - 5 gallon capacity
Up to 300 psi rating

Model ASBD-1

Model HEH-2

Model HT-6

Model BCFS-30-D

Model SF-2-HP

Summary of Contents for B-26S-D

Page 1: ...Form No 4002 Rev 7 08 BRYAN STEAM Boiler Accessories Improved performance and longevity for commercial and industrial boilers Since 1916 ...

Page 2: ...that are designed to handle hotter water and develop higher pressures at lower speeds Bryan Condensate Transfer Stations are ideal for remote or non accessible locations where unattended dependable performance is essential The Bryan horizontal boiler feed system is a conven tional stand mounted feed system that is completely packaged but is also flexible to meet each customers specific needs Featu...

Page 3: ... from 60 1000 gallons standard Larger sizes available upon request Factory packaged for ease of installation Packages based on 1 gallon storage per 1 BHP minimum Available with multiple pumps and different electrical packages Various pump manufacturers available mounted and wired TEFC pump motors and NEMA 12 enclosures are standard Heavy duty stand with pump platform Integral steam preheater optio...

Page 4: ...drop in boiler operating pressure which can occur when cold water is added Recycling of steam from vents and flash steam from traps that would otherwise be vented to the atmos phere can result in appreciable energy savings Mechanical deaeration by a feedwater deaerator can cut the amount of chemical consumables used for water conditioning for a continuing operating cost saving Reduce costs improve...

Page 5: ...s and are guaranteed to deliver deaer ated water at a maximum oxygen content of 005cc l 7 PPB and zero measurable CO2 All internal surfaces that come in contact with undeaerated water are con structed of type 304L stainless steel for long life and low maintenance Residence time for undeaerated water inside a tray type deaerator is longer providing more efficient deaeration particularly where wide ...

Page 6: ...Vertical Blowdown Tank The tanks are designed to hold one boiler blowdown and they meet stringent New Jersey and National Board standards Stainless steel wear plate pro tects inlet connection Large vent connection assures quiet operation Constructed and stamped to ASME code Sect VIII for 50 psig Wide range of stan dard sizes for boilers up to 200 psig Models for higher pressures available Blowdown...

Page 7: ...all of these enhanced boiler operating items Steam Exhaust Head Size ranges from 1 24 Overflow Trap Size ranges from 2 6 Automatic Blowdown System The Bryan exhaust head gives three levels of pro tection against oil and water pollution first an expansion chamber sec ond an impingement cone and third a catch trough and drain What one misses another gets resulting in oil free water free exhaust stea...

Page 8: ...are now available using an existing central boiler heating plant as the heat source Hot water or steam is taken from the heating main and cir culated thru the Exchanger shell The pool water is heated as it passes through the copper Indirect coil This installation diagram shows a typical application of the tank heater installed in the tank Horizontal or vertical tanks are available with tank heater...

Reviews: