7.1.1
Earthing / Grounding Screw (equipotential bonding)
WARNING
Sparking!
Fire hazard!
Ensure that Ground / Protective Earth is connected correctly!
A loose ground connection can lead to sparking and subsequent fires!
INFORMATION
The device is equipped with three ground connections. For safe operation, at least one
ground connector needs to be connected!
The grounding cable must be connected with the chassis of the vehicle and/or testing bay.
The cable diameter of the ground cable must correspond to cable diameter of the HV wiring.
Max. screw-in depth: 16 mm
Torque grounding screw (1) M6 x 19 = 12.5 Nm