Technical information
and start-up
Fast Charger
NLG6xx
26
6.3
Technical properties
High charging power up to 22 kW
1-phase and 3-phase charging supported
Galvanic isolation between mains and HV battery
No DC-
fault current possible, therefore the use of a Class A Ground Fault Interrupter is sufficient
Very compact and lightweight design ensuring high power density (1.8 kW/kg)
Patented Liquid Pin© cooling system for optimum temperature behaviour and maximum performance
Integrated Power Factor Correction
Power Ripple Compensation in 1-phase operation (PRC)
DC motor (actuator) control possible
2 x CAN interface: Vehicle CAN and diagnostic CAN (SW download via CAN feasible with special toolkit)
Mains side complies with IEC 61851-1 (
type 2 Mennekes
)
HV side complies with LV123
3 x LED output (PWM, configurable via CAN, high side driver)
Battery friendly charging even at high power, thanks to low battery current ripple
Evaluation of external PT1000 sensors
Vehicle WakeUp output to wake up the vehicle when the charging plug is plugged in
6.4
Basic function
The NLG6 transforms 1- or 3-phase alternating current into direct current and provides galvanic isolation
between the public AC grid and the HVDC system of the electric vehicle. This allows for charging the battery
on one hand, and on the other hand ensures the safety of both grids.
Battery charging is controlled by CAN, i.e. NLG6 limits current and voltage to the values received by CAN. If
for a certain time (ca. 0.5s) no such signals are received, the unit interrupts the charge in order to protect the
battery.
NLG6 contains an interface for IEC-61851 / SAE-J1772 signals, i.e. the respective safety signals and
protocols like Control Pilot and Proximity are served according to the standards. Additionally, there are
protection measures integrated in the unit (temperature detection and derating, fuses) to protect the unit from
overload and to interrupt the power flow in case of potentially dangerous situations and fault patterns.
Summary of Contents for NLG664-U0
Page 22: ...Technical information and start up Fast Charger NLG6xx 22...
Page 33: ...Technical information and start up Fast Charger NLG6xx 33 6 8 Block diagram...
Page 41: ...Technical information and start up Fast Charger NLG6xx 41 5 V conforms to no Crash...
Page 45: ...Technical information and start up Fast Charger NLG6xx 45...