5-13
Electrical Systems
Section 5
T-top Fuse Block
Main DC circuit 6 of 7
provides power to the fuse
block located inside the T-top electronics box.
This circuit is protected by one 60-amp, push button
breaker. The 60-amp breaker is located within seven
inches of the electronics battery switch.
One or two Group 27 105 amp hour, deep cycle batter-
ies (optional) power these circuits through the elec-
tronics battery switch. A three-battery system will
have an OFF-ON electronics battery switch. A four-
battery system will have a 1-2-ALL electronics battery
switch.
Ten branch circuits can be connected to the DC elec-
trical system at the T-top electronics fuse block. The
T-top electronics fuse block also has ten connection
points for the negative side of the DC electrical sys-
tem. Some electrical accessories were installed at the
factory.
See
Electrical Diagram
for wire color codes.
!
CAUTION
The total combined amperage ratings for all
accessories connected to the T-top electronics
fuse block must not exceed 60 amps. Overload-
ing the T-top electronics fuse block might
cause repeated tripping of the 60-amp breaker
and other electrical problems.