Operating instructions 

 

General requirements 

Please note that national and local provisions must be satisfied when installing the 

BRULA basic stove firebox. 

Please consult your competent district master chimney sweep about this prior to 

installation. 

He will advise you on the suitable chimney as well as all other requirements which 

are of relevance for the setup and commissioning of your basic stove. A sufficient 

combustion air supply must be ensured in particular, especially with a well sealed 

building shell, flat ventilation systems etc. in order to guarantee smooth operation. 

Your chimney sweep will be able to help here too. He will also check that the 

fireplace has been connected properly. 

The basic stove firebox described here is tested in accordance with EN 13229:2005-

10 taking into account the agreement as per Art. 15a B-VG (since 01.01.2015 in 

Austria only nominal load operation is permitted!). 

It may be attached to a chimney with multiple connections provided that the 

chimney's technical conditions allow this. 

If the basic stove is attached to a chimney with multiple connections, the heating door 

used must be self-closing. This ensures that the door closes automatically after 

adding more fuel and thus the supply pressure of the chimney is not affected. 

Installation site / fire protection regulations 

When setting up the small basic stove, the valid fire protection regulations of the 

German Fire Code Ordinance (FeuVo) must be observed. The specified minimum 

distances to combustible objects and walls must be maintained and the flooring must 

also be protected. 

Note on setting up the fireplace only on surfaces with a sufficient load bearing 

capacity. If the load bearing capacity is not sufficient, suitable measures must be 

taken (e.g., plate for load distribution) to remedy this. 

Caution: 

Thermal insulation / insulation design must be realised as per the specialist 

regulations of the stove and air heating construction trade (TROL) and the country-

specific provisions.

 

 

 

Summary of Contents for B

Page 1: ...1 Assembly and operating instructions www brula de ...

Page 2: ...asic stove principle The basic stove also known as a storage stove is synonymous with long lasting and healthy heating And these are precisely the advantages offered by this stove system Compared to a hot air system which uses the principle of convection and essentially only heats up the air a basic stove emits warmth into the room slowly and evenly in the form of healthy radiant heat something wh...

Page 3: ...ration is permitted It may be attached to a chimney with multiple connections provided that the chimney s technical conditions allow this If the basic stove is attached to a chimney with multiple connections the heating door used must be self closing This ensures that the door closes automatically after adding more fuel and thus the supply pressure of the chimney is not affected Installation site ...

Page 4: ...iance External dimensions H W D 875x500x500 Amount of wood 3 kg h Nominal heat output 3 5 KW Firing capacity 11 KW Mass flow of flue gas 11 g s Flue gas temperature Firebox burnout 400 C Ceramic draught 175 C Minimum delivery pressure 12 3 Pa Dust relating to 13 O2 31 mg Nm3 CO relating to 13 O2 855 mg Nm3 Efficiency 86 3 Weight 244 kg Reheating surface details Draught deflections 90 9x Constant d...

Page 5: ...ort time Heating up Approx 4 5 kg of small dry pieces of beech wood 2 to 6 cm in diameter with a max length of 35 cm and a handful of chippings are ideal for heating up Since the combustion air flows via the pane ventilation into the combustion chamber it should be ensured that the wood is stacked loosely in the combustion chamber The chippings are placed from above in the middle of the pile This ...

Page 6: ... of smoke form on the tips of the flames the combustion air was reduced too much According to 15a B VG since 01 01 2015 only nominal load operation has been permitted in Austria Maintaining the glowing embers After the flames have gone out an energy loaded firebed remains in the combustion chamber It can now be decided whether the fire should be revived with thin firewood and an open combustion ai...

Page 7: ...uel which can be placed in the stove for type B is 3 kg h Fireboxes and ceramic reheating surfaces must have a cavity wall construction and be gastight as per the specialist regulations TROL Do not store combustible items on the stove Metal items can become hot Your basic stove is not a waste incineration plant and should never be used for burning waste Just like all technical appliances your basi...

Page 8: ...cm between combustible objects and the stove door If fireplaces are installed in living areas and the combustion air is taken from the room where the fireplace is installed the operator must ensure that the fireplace is supplied with sufficient combustion air What to do in the event of a chimney fire Close the combustion air inlet and keep it closed Call the fire brigade and the chimney sweep Enab...

Page 9: ... not be used for lighting and must not be burnt Liquid fuels Moist or treated wood Wood chips or bark waste Chip boards or comparable coated and uncoated materials Plastics and foams All materials which are foreign to wood Paper cardboard All types of waste Your fireplace is not a mini waste incineration plant Please protect the environment and only use approved and suitable fuels Cleaning the fir...

Page 10: ...e scope of delivery of the basic stove firebox 1 x stove door platform 1 x dipping mortar 4 x corner stone with hole 16x corner stone 17x intermediate stone 2 m sealing tape 1 x clip set 4x recessed corner 2x recessed centre 1x combustion kit 1x top plate stone 2x horizontal clip 2x horizontal clip 1x protective glove ...

Page 11: ...he Allen screw on the lower hinge with a 2 5 mm Allen key The door stop screw below the frame is then unscrewed with a spanner Grasp the door from below With a slight lifting motion lift the door slightly so that the lower pin of the hinge is exposed In this position pull the door down and a little forward Now let the door drop a bit so that the door can be slid and removed from the upper track ...

Page 12: ...12 Operating instructions Assembly instructions stove door platform Remove the panel V ...

Page 13: ...doors 2 Self adhesive sealing tape must be applied to the stove doors prior to installation 3 The combustion kit can be attached individually Horizontal clip Corner stone with hole Stick in the round bar to seal the opening above the burnout Combustion kit enables burnout to the side or rear Horizontal clip Only materials and spare parts that have been approved by the manufacturer may be used ...

Page 14: ...chimney open the room doesn t get warm enough Are the heating requirements too high the appliance too small The stove does not draw properly Is the firewood too moist Has too little wood been placed on the fire the room gets too warm Is the supply pressure too high Has too much wood been placed on the fire smoke escapes when adding fuel The firebox door was opened too quickly The supply pressure i...

Page 15: ...assembly and operating instructions Technical changes to the device by third parties Fragile parts such as glass This product has been manufactured in compliance with current standards of quality control The materials used have been carefully selected and like the production process are subject to on going quality control Specialist knowledge is required when assembling and installing the product ...

Page 16: ...ple connection is permitted satisfies Level 2 BlmSchV Ordinance in the Implementation of the Federal Immission Control Act CO concentration at 13 O2 content 0 069 percent by volume Exhaust gas temperature based on reheating surface 175 C Firing capacity 5 8 11 kW Efficiency 86 3 Distance from combustible components to rear wall 300 mm to side walls 300 mm to front 800 mm Only use recommended fuels...

Page 17: ...ciency index EEI 115 0 Nominal heat output Pnom kW 9 5 Direct heat output kW 9 5 Indirect heat output kW Thermal efficiency at nominal heat output ηth nom 86 3 Auxiliary current consumption at nominal heat output elmax kW 0 0 Auxiliary current consumption at minimum heat output elmin kW 0 0 Auxiliary current consumption in standby mode elSB kW 0 0 Type of heat output room temperature control no ro...

Reviews: