Translation of the Original Operating Instructions
VP-80/VP-80 E
109
Tab. 11 Balancer setup parameters
Correction
type
Polar correction; Fixed location; Fixed
weight
A)
Polar correction
With polar correction the weight and its
application point are freely selectable.
B)
Component correction
With component correction 3 - 99 fixed
locations can be selected (e.g. fan vanes,
equidistant holes on rotor circumference).
The test weights are mounted in a fixed
location for the trial run. VIBROPORT 80
calculates the correction weights for two
(adjacent) component locations.
C)
Fixed weight correction
With fixed weight correction the weight is
preselected. The fixed weight is mounted
in any location for the trial run. The
VIBROPORT 80 calculates the two loca-
tions of the identically fixed correction
weights.
Num Compo-
nents
e.g. 5
Depends on whether
Component has been
selected under Correc-
tion Type.
Fixed Weight
e.g. 100 g
Depends on whether
Fixed Weight has been
selected under Correc-
tion Type.
Parameter
Setting para-
meter
Explanation of para-
meter