135
Network Troubleshooting Chart
OBSERVATION
POSSIBLE CAUSE
PROCEDURE
“0” displayed in data fields.
Data sources are not configured.
Use DATA SRCS menu to configure data
source.
ICON
system does not power on.
Power Supply Harness fuse is blown.
Check Power Supply Harness, fuses and
switched B+ from the ignition harness. See
Note
below.
Power Supply Harness blown
fuse.
Network current draw is exceeding 3A.
Check all connections and wiring. Disconnect
accessory connections to network. Isolate pos-
sible overloads or shorted accessory.
No speed display.
Requires input from
NMEA 2000
Speed
transducer, GPS or paddle wheel.
Check that the device is installed and con-
nected to the network.
Speed Over Water (SOW) does
not display.
Speed Over Ground (SOG) does
not display.
Requires input from
NMEA 2000
GPS.
Water depth does not display.
Requires
NMEA 2000
depth transducer.
Sea water temperature does not
display.
Requires
NMEA 2000
temperature trans-
ducer or analog sender.
Fuel tank level does not display.
Requires fuel level sensor or analog
sender.
No “FUEL ECON”.
Requires input from
NMEA 2000
GPS.
Note:
The tachometer harness of the
ICON
gauge network must be connected to the
NMEA 2000
network using the device port
of a t-connector. Misaligned t-connectors can cause the
NMEA 2000
network power supply fuse to blow and disrupt or elim-
inate communication in the system.
Summary of Contents for Evinrude E-TEC Icon Pro Series
Page 2: ......
Page 7: ...ICON PRO SERIES Gauge Setup ...
Page 32: ...30 ...
Page 33: ...Tachometer Operation ...
Page 109: ...Speedometer Operation ...
Page 130: ...128 ...
Page 131: ...Troubleshooting ...
Page 139: ...Reference ...
Page 145: ...143 Notes ...
Page 146: ...Product Warranty ...
Page 150: ...148 ...
Page 152: ......
Page 154: ......
Page 155: ......