S-7200A
10. TREADLE UNIT ASSEMBLY
48
10-2. Standard setting values
Specification
Treadle unit G
Treadle unit H
Operation
Does not control automatic
presser lifter
Controls automatic presser lifter
Spring position setting
No forward/back 1st step
modulation
(Figure [a] on previous page)
Forward/back 1st step
modulation
(Figure [b] on previous page)
Function
No.
Symbol
(diagram
below)
Function
Length from S0
(mm)
Force (N)
Length from S0
(mm)
Force (N)
- S0
Neutral point
0 - 0 -
82 S1
Forward automatic presser
lifter operating point
-
-
2 (NOTE 1)
10
83 S2
Low speed operation
starting point
3 10 5 25
84 S3
Speed change starting point
6 - 7 -
85 S4
Maximum speed reaching
point
S5-1 - S5-1 -
- S5
Maximum forward
depression point
14.5 12 14.5 32
81 S6
Back automatic presser
lifter operating point
-
-
2 (NOTE 2)
14
80 S7
Thread trimmer operating
point
5 22 5 35
- S8
Maximum back depression
point
8 28 8 43
(NOTE 1) Setting is enabled when DIP switch 1 is set to ON and Function No. 13 is set to "1".
(NOTE 2) Setting is enabled when Function No. 12 is set to "0".
・
When the connecting rod installation position is on the inside, the measurement value is the amount of movement of the
treadle from the neutral position to the forward position and to the backward position.
・
For treadle unit -H, the point of change (F) in the forward depression force is between S1 and S2, and the point of change
(R) in the backward depression force is between S6 and S7.
Speed
Backward depression
Neutral
Forward depression
1841M