S-7200A
4. FUNCTION SETTINGS
18
Function No. 108
−
114
No.
Initial value
Setting range
Setting details
108
(NOTE 30)
0 (needles)
0
–
99 (needles) Number of stitches for option output (C1)
109
(NOTE 31)
10 (ms)
0
–
990 (ms)
Delay time until option output turns on (C2)
110
(NOTE 31)
0 (ms)
0
–
990 (ms)
Option output on time (C3)
111
(NOTE 32)
0 (ms)
0
–
990 (ms)
Delay time until option output turns on (C4)
112
(NOTE 33)
2000 (ms)
0
–
9900 (ms)
Option output on time (C5)
113
(NOTE 34)
0 (needles)
0
–
99 (needles) Number of stitches for option output (C6)
114
(NOTE 34)
0 (needles)
0
–
99 (needles) Number of stitches for option output (C7)
(NOTE 30) Setting is enabled when Function No. 70 is set to "2".
(NOTE 31) Setting is enabled when Function No. 70 is set to "4".
(NOTE 32) Setting is enabled when Function No. 70 is set to "5".
(NOTE 33) Setting is enabled when Function No. 70 is set to "2" or "5".
(NOTE 34) The stitch number control output signal can be set in accordance with the variable input signal.
<Stitch number control output signal>
The variable input signal should be connected to connector CN6. The output signal is sent to connector CN11.
NOTE:
If Function No. 112 and No. 113 are set to "0", output is synchronized with the variable input signal.
Motor
Variable input signal
Needle up signal
Output signal
External input
External output; signal is open collector output within maximum 10 mA
2262M
2263M