III- 36
[ 4 ]
Installing the Upper Cover
(1) Insert the tape sensor PCB ASSY into the insert guide.
Note1: Insert the tape sensor PCB ASSY until it hits the
groove of the insert guide.
Note2: Confirm that you can see the tape sensor PCB ASSY from the hold of the insert
guide.
Note3: Fold the flat cable after assembling the tape sensor PCB ASSY.
Important: When replacing the tape sensor PCB ASSY, and then check the items
using the “MAINTENANCE SOFTWARE OPERATION” in APPENDIX 1.
Fig.3.2-14 Installing the Upper Cover (1)
(2) Put the flat cable of tape sensor PCB ASSY into the hole on the upper cover.
(3) Assemble the insert guide onto the upper cover with the two screws.
Fig.3.2-15 Installing the Upper Cover (2)
Tape sensor PCB ASSY
Insert guide
Insert guide
Screw
Insert guide
Flat cable
Groove
Groove
Flat cable
Tape sensor PCB ASSY
Screw
Upper cover
Hole
Upper cover
Hole