(4) Remove the paper from the main unit, and then click the [Sensor black level check
(2)] button. If the standards are satisfied, “OK” is displayed in the “Black level:”
column.
(5) If all the check results are OK, click the [OK] button to go on to the next test.
Important: If NG appears in the “Adjust value” column, implement the operation
described in “APPENDIX 1.3 Use Procedure of the VR Adjustment
Tool (ql500tstVRAdjust.exe)”.
Fig. 13
12
Summary of Contents for QL 570 - P-Touch B/W Direct Thermal Printer
Page 1: ...P touch SERVICE MANUAL MODEL QL 570 ...
Page 29: ...III 4 Grease to be used Silicon grease G501 rice grain sized Platen gear Double gear C ...
Page 84: ...IV 6 4 5 TROUBLESHOOTING FLOWS 1 Printing is performed with specific dots omitted ...
Page 85: ...IV 7 2 The tape is not detected correctly ...
Page 86: ...IV 8 3 LED does not turn on ...
Page 87: ...IV 9 4 No printing is performed 5 The interface malfunction ...
Page 88: ...IV 10 6 The tape is not cut ...
Page 89: ...IV 11 7 The tape is not fed correctly ...
Page 122: ...Sep 2007 SM PT002 3 ...