4-12
4.8.2 Installing the Y-diversion Lever Assy
1. Mount the Y-diversion lever assy on the X-cutter unit by inserting the left end into
chassis L then the right end into chassis R.
Y-diversion lever assy
X-cutter unit
Fig. 4.8-2 Installing the Y-diversion Lever Assy 1
2. Press each of the two Y-cutter assy’s against the Y-diversion lever assy and move it
in the direction of arrow 1 up to the position of the Y-cutter guide L/R.
3. Install the Y-cutter guides by lifting the tab on each Y-cutter assy in the direction of
arrow 2, then pushing in the direction of arrow 3 to engage the hook.
Y-cutter assy
Y-cutter guide R
Y-cutter guide L
1
2
3
1
2
3
1
2
3
Fig. 4.8-3 Installing the Y-diversion Lever Assy 2