3-12
3.4 Chassis
3.4.1 Removing the Harness Connectors
Remove 12 harness connectors from the main PCB. Do not remove the power
harness assy (red/black CN13).
Power harness assy
Fig. 3.4-1 Removing the Harness Connectors
3.4.2 Removing the PE Sensor Unit
Open the bearing supports in the bottom cover outward. Lift the PE sensor unit out
of the bottom cover bearing supports. Pull the tip of the PE sensor unit off the
paper feed roller shaft and remove the PE sensor unit. Take care not to damage
the tip of the PE sensor unit when disconnecting it.
Fig. 3.4-2 Removing the PE Sensor Unit
Paper feed roller Assy
PE sensor unit
Bearing supports