- IV-37 -
2.3.25 Chute ASSY REGI
1) Release the 2 hooks securing the housing ASSY ELEC to the printer and remove
the housing ASSY ELEC upward.
Fig.4-65
2) Disconnect the 2 connectors of the chute ASSY REGI from the printer.
3) Remove 4 screws securing the chute ASSY REGI to the printer.
4) Lift the left end of the chute ASSY REGI and pull out the chute ASSY REGI
leftwards from the printer.
Note:
Take care not to damage the plastic film when refitting the chute ASSY REGI.
Fig.4-66
Housing ASSY ELEC
Chute ASSY REGI
Screw, M3x10
Screw, M3x10