Error code 64 (C)
Error code 65 (M)
Error code 66 (Y)
Error code 67 (K)
Each toner cartridge will reach the end of life soon.
<User Check>
- Gently shake the toner cartridge of the appropriate color from side to side and install it again.
- Replace the toner cartridge of the appropriate color.
■
Error code 68
Fuser unit error.
(The temperature rise is detected even after the halogen heater is turned OFF.)
Error code 69
Fuser unit error. (The connector of the center thermistor is inserted incorrectly.)
This error does not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
<User Check>
- Turn OFF the power switch, and turn it ON again after a while.
Toner Low (C)
Prepare New Cyan (C) Toner Cartridge.
Toner Low (M)
Prepare New Magenta (M) Toner Cartridge.
Toner Low (Y)
Prepare New Yellow (Y) Toner Cartridge.
Toner Low (K)
Prepare New Black (K) Toner Cartridge.
Step
Cause
Remedy
1
Toner/New sensor PCB ASSY
failure (Toner empty)
Replace the Toner/New sensor PCB
ASSY.
2
Engine PCB failure
Replace the engine PCB ASSY.
3
Main PCB failure
Replace the main PCB ASSY.
Print Unable 68
Turn the power off and then back on again.
Print Unable 69
Turn the power off and then back on again.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for 09055CDN
Page 22: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 37: ...Confidential CHAPTER 2 ERROR INDICATION AND TROUBLESHOOTING ...
Page 47: ...2 8 Confidential ADF part A4 model Fig 2 6 Left side Right side Document feed path Face up ...
Page 48: ...2 9 Confidential ADF part Legal model Fig 2 7 Left side Right side Document feed path Face up ...
Page 180: ...Confidential CHAPTER 3 DISASSEMBLY AND ASSEMBLY ...
Page 211: ...3 28 Confidential 8 DISASSEMBLY FLOW Disassembly Re Assembly second ...
Page 212: ...3 29 Confidential Disassembly Re Assembly second ...
Page 416: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 436: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 445: ...5 7 Confidential Black and white scanning First side Front Fig 5 1 ...
Page 446: ...5 8 Confidential Black and white scanning Second side Back Fig 5 2 ...
Page 447: ...5 9 Confidential Color scanning First side Front Fig 5 3 ...
Page 448: ...5 10 Confidential Color scanning Second side Back Fig 5 4 ...
Page 475: ...5 37 Confidential Cover page sample Fig 5 18 End page sample Fig 5 19 ...
Page 482: ...5 44 Confidential Inter color position alignment adjustment chart Fig 5 23 ...
Page 491: ...5 53 Confidential Color test pattern Fig 5 28 MCYK Y C K M YCMK_ _A ...
Page 512: ...Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 514: ...6 1 Confidential 1 CIRCUIT DIAGRAMS High voltage Power Supply PCB Circuit Diagram 1 3 ...
Page 515: ...6 2 Confidential High voltage Power Supply PCB Circuit Diagram 2 3 ...
Page 516: ...6 3 Confidential High voltage Power Supply PCB Circuit Diagram 3 3 ...
Page 517: ...6 4 Confidential Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 518: ...6 5 Confidential Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 519: ...6 6 Confidential NCU PCB Circuit Diagram U S A Canada ...
Page 520: ...6 7 Confidential NCU PCB Circuit Diagram Europe Oceania ...
Page 521: ...6 8 Confidential NCU PCB Circuit Diagram China Asia South Africa Gulf ...
Page 523: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 581: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 585: ...Confidential APPENDIX 3 INSTALLING THE MAINTENANCE DRIVER ...
Page 589: ...App 3 4 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...