5-15
Confidential
* For more information on the worker switch, refer to Appendix.
<Operating procedure>
(1) Press the
1
and
0
buttons in this order in the initial state of the maintenance mode.
The machine displays "WSW00" on the LCD and becomes ready to accept a worker
switch number.
(2) Enter the desired number from the worker switch numbers (01 through 78). The following
appears on the LCD.
(3) Enter a value to be set (0 or 1) using the
0
and
1
buttons.
(4) Press the
OK
button. This operation saves the newly entered selector values onto the
EEPROM and readies the machine for accepting a worker switch number.
(5) Repeat steps (2) through (4) until the modification for the desired worker switches is
completed.
(6) When the
Stop/Exit
button is pressed, the machine beeps for one second and returns to
the initial state of the maintenance mode.
WSW68
Reserved (Change of the setting is prohibited)
WSW69
Reserved (Change of the setting is prohibited)
WSW70
Reserved (Change of the setting is prohibited)
WSW71
Reserved (Change of the setting is prohibited)
WSW72
Reserved (Change of the setting is prohibited)
WSW73
Reserved (Change of the setting is prohibited)
WSW74
ADF stop control
WSW75
Paper feeding parameter for turning the document counter when the
machine takes action duplex scanning
WSW76
The limited number of the documents in reverse for paper ejection of the
simplex scanning from ADF
WSW77
The limited number of the documents in reverse for paper ejection of the
duplex scanning from ADF
WSW78
Recording stop function when the drum reaches the end of life
WSW79
Function setting 27
Memo:
- To cancel this operation and return to the machine to the initial state of the maintenance
mode during the above procedure, press the
Stop/Exit
button.
- If there is a pause of more than one minute after a single-digit number is entered for
double-digit worker switch numbers, the machine will automatically return to the initial
state of the maintenance mode.
WSW No.
Function
Selector 1
Selector 8
Summary of Contents for 09055CDN
Page 22: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 37: ...Confidential CHAPTER 2 ERROR INDICATION AND TROUBLESHOOTING ...
Page 47: ...2 8 Confidential ADF part A4 model Fig 2 6 Left side Right side Document feed path Face up ...
Page 48: ...2 9 Confidential ADF part Legal model Fig 2 7 Left side Right side Document feed path Face up ...
Page 180: ...Confidential CHAPTER 3 DISASSEMBLY AND ASSEMBLY ...
Page 211: ...3 28 Confidential 8 DISASSEMBLY FLOW Disassembly Re Assembly second ...
Page 212: ...3 29 Confidential Disassembly Re Assembly second ...
Page 416: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 436: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 445: ...5 7 Confidential Black and white scanning First side Front Fig 5 1 ...
Page 446: ...5 8 Confidential Black and white scanning Second side Back Fig 5 2 ...
Page 447: ...5 9 Confidential Color scanning First side Front Fig 5 3 ...
Page 448: ...5 10 Confidential Color scanning Second side Back Fig 5 4 ...
Page 475: ...5 37 Confidential Cover page sample Fig 5 18 End page sample Fig 5 19 ...
Page 482: ...5 44 Confidential Inter color position alignment adjustment chart Fig 5 23 ...
Page 491: ...5 53 Confidential Color test pattern Fig 5 28 MCYK Y C K M YCMK_ _A ...
Page 512: ...Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 514: ...6 1 Confidential 1 CIRCUIT DIAGRAMS High voltage Power Supply PCB Circuit Diagram 1 3 ...
Page 515: ...6 2 Confidential High voltage Power Supply PCB Circuit Diagram 2 3 ...
Page 516: ...6 3 Confidential High voltage Power Supply PCB Circuit Diagram 3 3 ...
Page 517: ...6 4 Confidential Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 518: ...6 5 Confidential Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 519: ...6 6 Confidential NCU PCB Circuit Diagram U S A Canada ...
Page 520: ...6 7 Confidential NCU PCB Circuit Diagram Europe Oceania ...
Page 521: ...6 8 Confidential NCU PCB Circuit Diagram China Asia South Africa Gulf ...
Page 523: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 581: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 585: ...Confidential APPENDIX 3 INSTALLING THE MAINTENANCE DRIVER ...
Page 589: ...App 3 4 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...