200707_3
27
Servicing Instructions
Servicing should be carried out annually by a qualified installation engineer when
the stove is cold and the gas supply is turned off at the isolation tap. The
following points should be checked.
Remove the coals and clean any dust and debris from the top of the burner
unit. Ideally a vacuum cleaner should be used, but a soft brush will do.
Check the condition of the coals. Any damaged ones will affect the efficient
operation of the stove and should be replaced with new ones available from
your stove supplier.
All gas supply joints should be checked to make sure they are completely
sealed and that the gas supply and pressure is to specification.
The pilot jets are correctly set and clear of obstruction.
The chimney should also be checked to make sure there are no restrictions or
blockages.
Finally re-lay the coals and re-light the stove as described previously.