Broseley WINCHESTER Installation & Operating Instructions Manual Download Page 20

200707_3 

 

20 

 

Operating the Stove   - Remote Control Version (Handset) 

 

Setting the temperature display to Celsius or Fahrenheit

 

 
Press and release the + or - button to toggle between C and F.  
When the display shows the desired symbol, press and releases the 
“SET” button to store. 
 
As the important settings above have now been done, press and hold 
for a few seconds the “SET” button for a few seconds and this will exit 
the setup menu. The control is now ready for use with the Fire Control. 
 

Paging the handset 
 

If you have misplaced the handset you can page it by pressing the + button only on the 
fire control for around 5 seconds. The handset will flash and make a noise to help you to 
locate it. Once you pick up the TESC it knows you hold it and so the sound stops. The 
flashing and sound will last for 60 seconds each time the handset is paged as described. 
If not found in 60 seconds, page again and so on. NOTE: PRESS “+” Button ONLY, NOT 
“+” and “-‘Together as you will accidentally break the handset pairing and have to reset 
handset to factory state and pair again (see other parts of the booklet if this happens). 
Note: the legend at the bottom shows the battery condition of both the batteries in the 
hand set and in the fire control alternately. RC = Remote Control handset and FC = Fire 
control.  The control is designed to get the most out of the batteries but when eventually 
the display shows they are spent(when the battery legend is an empty area, we 
recommend you change the batteries in the handset before they are flat, to avoid having 
to re-program the time of day in again. N.B. Pairing is not lost, even if the batteries are 
removed or flat. 
 

Advanced settings Menu 

 
In the event that you may want to change the other pre-set settings of the control 
features. Do not do a long press and hold above but a normal short press and release 
will take you into the advanced settings area. 
 
Advanced settings options are:- 

  Back light –  

o

  A = Automatic (default setting). The back light comes on in the dark but 

not in the light. 

o

  0 = Light never comes on. 

o

  1 = Light comes on whenever handset is unlocked. 

  Display contrast – 8 levels from 0 to 7 (default level 4). 

  P = pairing with other devices other than the fire control. The hand set can pair 

with other modules to :- 

L= Operate an electric light – which is the dimmable in 9 steps 

o

  F= operate an electric fan –which can have 9 speed levels 

o

  A= operate an auxiliary contact to operate another device. 

 
 
 

Summary of Contents for WINCHESTER

Page 1: ...E THESE INSTRUCTIONS WITH THE USER Broseley Fires do not provide flue pipes closure plates or any other associated accessory Please note gas installations MUST only be carried out by installers who ar...

Page 2: ...tallation 7 Connecting the TTB sensor 8 Positioning the Coal Ceramics 9 Positioning the Log Ceramics 12 Gas Connection Pressure Testing 13 Spillage Testing 14 Operating the Stove 15 The Remote Control...

Page 3: ...d accredited gas fitter listed on the Gas Safe register Please Note THE INSTALLATION MUST BE CARRIED OUT BY A GAS SAFE REGISTERED ENGINEER IN ACCORDANCE WITH THE GAS SAFETY INSTALLATION AND USE REGULA...

Page 4: ...6 6 kW hr Max Heat Ouput 5 5 kW hr Supply Pressure 20 mbar Gas Rate 0 611 m3 Hr Injector Size 460 Spigot diameter 125mm 5 Weight 116 Kg Please note this product is designed to only use natural gas Dim...

Page 5: ...Rear Non Combustible 75mm Side Combustible 610mm Non Combustible 100mm Hearth Protrusion in front of the appliance 50mm Shelf Distance combustible material 610mm Please note these are minimum clearanc...

Page 6: ...eally it is recommended that the flue run is as straight as possible using the top outlet on the stove When using the rear outlet if alignment of the top outlet is not possible a T shaped flue section...

Page 7: ...hat the L brackets line uo with the screw holes in the internal rear plate 3 Next with the stove stood upright insert the burner control first through the door Dip the controls through the bottom of t...

Page 8: ...burner installed thread the TTB connection cable from the interrupter to the TTB sensor mounted on the rear panel of the stove TTB sensor located just below the rear flue outlet Thermo Couple To Gas...

Page 9: ...so always handle with care when fitting them Follow these instructions carefully Ceramics that are positioned wrongly could seriously alter the performance of your appliance Step 1 Open the door fully...

Page 10: ...via the location holes and lugs Ensure the flat rear side of the ceramics is against the back of the stove Step 3 Take the smaller of the rear ceramics right hand side and locate it into position on...

Page 11: ...the flames from burning evenly and effectively The path of the flame should not be obstructed Finally close the stove door and wind on the M6 x 18 hex bolt back onto the door fixing bolt slide the ha...

Page 12: ...age Two Stage Three Position the rear log onto the two location Position the next log as shown in lugs towards the rear of the base ceramic the diagram below This log also as shown in the diagram Has...

Page 13: ...lways make sure that there is adequate gas pressure and volume to the stove The relevant pressures are on the ID plate on the gas control knob 1 For natural gas this is 20mbar measured at the burner t...

Page 14: ...ed the device will recognise the fault as an increase in heat inside the stove and shut the appliance down within a safe period so that there is no excessive build up of products of combustion inside...

Page 15: ...hear a click Repeat until the pilot lights 3 Keep knob depressed at this point for 15 20 seconds 4 Upon releasing turn the knob anti clockwise until it stops in the permanent pilot light position The...

Page 16: ...the and buttons After fitting the batteries and replacing the cover the fire can now operate Slide the power isolator switch to the right to the on I position To start the fire press the power button...

Page 17: ...e rear of both sides of the button area control The green unlock light will illuminate Keep the handset held to keep the control unlocked to enable operation of the buttons Then with the other hand to...

Page 18: ...und the rear of both sides of the button area control The green unlock light will illuminate Keep the handset held to keep the control unlocked i e the green light on at all times to enable operation...

Page 19: ...es back to the previous parameter and change the display parameter Setting the display for 12 or 24 Hour display The H indicates that it is time to set the timer to either 24 hour display or 12 Hour A...

Page 20: ...egend at the bottom shows the battery condition of both the batteries in the hand set and in the fire control alternately RC Remote Control handset and FC Fire control The control is designed to get t...

Page 21: ...n initial installation Check understanding of control operation is understood If either the handset is reset or the gas control has the pairing operation buttons operated the pairing that existed will...

Page 22: ...s N B If the display returns to the one shown above with the word TESC shown then too much time has passed before pressing SET and so the handset has not paired yet Simply repeat pairing again N B Onl...

Page 23: ...showing this set temperature press the and buttons to alter the setting When finished either press set or leave and after a few seconds the new setting will be accepted and the display will return to...

Page 24: ...e in the weather The control must be left in the appropriate mode for this to function Note As stated in an earlier section snooze function can also be operated in conjunction with thermostat mode The...

Page 25: ...is installed by a qualified and accredited GAS SAFE installation engineer Improper installation adjustment alteration service or maintenance can cause personal injury and or damage to property If you...

Page 26: ...ing sound you hear is normally caused by dirt obstructing the pilot This is normally cured by carrying out the cleaning process outlined in the next section entitled Servicing Instructions After alter...

Page 27: ...ut a soft brush will do Check the condition of the coals Any damaged ones will affect the efficient operation of the stove and should be replaced with new ones available from your stove supplier All g...

Page 28: ...cessive __________ Is there any permanent ventilation in the room ____________________ Has the room double glazing ______________ Is the aeration of the pilot correct __________ Does the flame encircl...

Page 29: ...YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 4TH YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 5TH YEAR SERV...

Page 30: ...ance with our instructions or Repairs or modifications have been carried out by the purchaser or any third party not authorised by us or The appliance has been misused or accidentally damaged or Damag...

Page 31: ...Floor Unit B Knights Court Archers Way Battlefield Enterprise Park Shrewsbury Shropshire SY1 3GA Product Fiche Manufacturer Broseley Fires Ltd Model No Winchester Gas Stove Top Flue Winchester Gas Sto...