Hotspur 5 & 9 Issue 2 December 2017
12
Ventilation Requirements
Only install a dedicated external air kit supplied or specified by Broseley Fires, and
which is installed in a way that meets all required provisions of the manufacturer’s
instructions, local Building Regulations requirements and appropriate standards. The
details and minimum specification below must be followed at all times. Broseley Fires
stocks the Direct External Air Supply Kit that suits this product. It can be purchased
directly. Its specific code when ordering is
O-DEAS/KIT/100/WHITE
-
White coloured outside ventilator
O-DEAS/KIT/100/TERRA
-
Terracotta coloured outside ventilator
O-DEAS/KIT/100/SAND
-
Buff/Sand coloured outside ventilator
O-DEAS/KIT/100/BROWN
-
Brown coloured outside ventilator
O-DEAS/KIT/100/BLACK
-
Black coloured outside ventilator
The kit contains the following:
1 x 6x6' Louvre Ventilator
– available in White, Terracotta, Buff/Sand, Brown & Black
1 x 6x6' Louvre Back plate with 97mm Diameter Spigot
1 x 1.5m of Semi Rigid Aluminium Duct - 102mm (4 inches) Diameter
2 x 100mm Diameter Jubilee Clips
The minimum diameter of duct is 102mm (4 Inches)
The maximum total length of the duct is 1.5m
Assessment of the Property
Before any installation is carried out using a DEAS Kit the property must be fully
assessed to ensure there is enough ventilation (air-flow) available for combustion during
use and when the door is open for refuel. The following table gives advice on the
properties construction which can have an effect on its air permeability attributes. The
recommendations in this table should be used as a guide at all times.