200768_1
20
Trouble-shooting
The main burner does not seem to burn correctly or will not stay alight
Ensure gas pressures and flow rates are correct.
Test with all ceramics removed
Confirm that the flame pattern is even across the surface of the burner by removing
all of the ceramics. Only do this once pressures and flow rates are confirmed as
being correct.
Double check all ceramics are re-positioned correctly.
Ensure you have between 1mm and 3mm gap from the head of the pilot to the base
plate (base plate may have moved in transit)
Once all the above checks are completed, leave the appliance in a fully commissioned
state.
1 – 3mm
1 – 3mm Gap