background image

 

E1 

SECTION E 

 

BILGE SYSTEM AND FRESHWATER SYSTEM 

Description of Bilge System 

The two main engine room bulkheads divide the bilges up into three sections; 
forward cabin, engine room, aft cabin. Water from the forward cabin can only 

pass into the aft cabin bilge by means of a pipe running through the engine room 

thus the engine room bilge is isolated from the rest of the boat. 

Bilge Pumps 

Water from the forward cabin automatically drains into the aft cabin bilge 
from where it can be pumped overboard with the ‘Whale’ gusher 15 manual 

pump. A smaller ‘Whale’ manual pump is fitted in the engine room to deal 

with oil and water under the engines. 

Location 

The ‘Gusher’ 15 pump is situated in the engine compartment. 
The Whale lightweight bulkhead pump Mk. II is mounted on the side of the 

battery box situated between the engines. 

Manufacturer of Whale Pumps 

Munster Simms Engineering Ltd., 

Belfast. 

Description of Freshwater System 

Fresh water is contained in two stainless steel tanks with a total capacity of 

80 gallons approximately. The port tank contains 56 gallons approximately. 

The starboard tank contains 24 gallons approximately. 

The tanks are situated in the aft cabin under the port berth and under the 
head of the starboard berth. 

They are permanently connected by a balance pipe. 

The water is drawn from the port tanks by the Godwin automatic pump 
which has a pressure control switch which is activated as soon as a tap is 

turned on. Cold water is supplied from the pump to the forward toilet, galley 

taps and water heater, aft toilet taps and shower. Hot water is supplied 

from the heater to both toilets, shower and galley. 

A shut-off valve is fitted on the Godwin pump on the supply line from the 
tank. The water supply can thus be turned off should the pump need 

maintenance. 

Do not run the pump with the water supply cut off. 

Both tanks are filled from one deck filler situated on the port side. Both 

tanks are fitted with through-hull breathers. An electrical tank gauge can be 

fitted as an extra when it is situated in a prominent position in the galley. 

Summary of Contents for 35 European

Page 1: ...Broom 35 European Owners Manual Front Cover Original missing...

Page 2: ...ON B ENGINES AND GEARBOXES 1 Introduction Page B1 2 Perkins Workshop Manual B1 3 Lubricating Oils B1 4 Cold Start Aide B1 5 Routine Maintenance B1 6 Spares and Service B1 Location of Equipment Chart B...

Page 3: ...Fuel Tanks F1 Bleeding the System F1 Routine Service F1 Diagrammatic Lay out F2 SECTION G GAS SUPPLY SYSTEM 1 Description Page G1 2 Distribution G1 3 Changing Cylinders G1 4 Diagrammatic Lay out G2 Bo...

Page 4: ...ines check visually that sea water is discharging through exhaust outlets 5 Check bilges P E1 2 EVERY WEEK Remove engine sea inlet strainers and clean if necessary EVERY 50 HOURS Screw down rudder sto...

Page 5: ...ily procedure P A2 4 LEAVING THE VESSEL When leaving the vessel for any prolonged length of time it is recommended that the following procedure should be carried out ITEM ACTION REFERENCE 1 Turn off t...

Page 6: ...initially is SHELL RIMULA 20 20 W For the gearboxes only class A transmission fluids must be used The oil initially put into the gearboxes is SHELL DONAX T7 ATF N B On no account must engine oil be us...

Page 7: ...No 1 Engine Oil Filler Stbd No 3 P 8 Floorboard No 3 Engine Oil Dipstick Port Floorboard No 1 Engine Oil Dipstick Stbd Floorboard No 3 Gearbox Oil Filler Port No 13 P 8 Under Steps Gearbox Oil Filler...

Page 8: ...g off the engine throttles can be opened whilst leaving the gearbox levers in the neutral position This is achieved by pulling each control lever sideways from its pivot point before pushing forward t...

Page 9: ...ube and stuffing box The tube is packed with grease and provided with a grease cup The stock is held at the top by the steering arm Rudder Maintenance The grease cup should be turned down a couple of...

Page 10: ...C3...

Page 11: ...aintenance The gland should never be over tightened but should be tight enough so as to allow a drip of water to issue from the gland every 30 seconds approximately The graphite packing should be repl...

Page 12: ...water is contained in two stainless steel tanks with a total capacity of 80 gallons approximately The port tank contains 56 gallons approximately The starboard tank contains 24 gallons approximately T...

Page 13: ...r the hatch between the toilet and galley The seacocks for the aft toilet can be found under the forward floorboard in the aft cabin Shower The shower in the aft cabin toilet is equipped with a Jabsco...

Page 14: ...E3...

Page 15: ...tion pump The fuel tanks are filled by one deck filler situated on the starboard side which fills the main tank and the aft tank via the balance pipe Warning Tanks should be replenished in ample time...

Page 16: ...F2...

Page 17: ...stribution One cylinder and regulator supplies gas directly to the refrigerator The other regulator draws gas from two cylinders and the feed pipe divides up in the galley to supply the cooker and wat...

Page 18: ...G2...

Page 19: ...G3...

Page 20: ...ed in a box in the bilge between the engines Each set of engine batteries has an isolating switch on one of the terminals NOTE It is advisable to turn off all the current at the battery master switche...

Page 21: ...e manufacturers literature supplied with this manual The manufacturer of Seafarer Echo Sounder is Electronic Laboratories Ltd For address see page S1 The transducer is fitted in front of the port or s...

Page 22: ...H3...

Page 23: ...itch clockwise to the Start position The switch will slowly return to the fullheat position On starting the glowplug becomes energised indicated by the yellow lamp After approximately 20 30 seconds th...

Page 24: ...n position This will allow the motor and fresh air fan to run alone NOTE The HL3 003 unit does not have a clutch The pump runs dry Only the solenoid is de energised AT NO TIME MUST VENTILATION BE SELE...

Page 25: ...Telephone Norwich 410441 Supplier of Perkins Engines Dunlop Ltd Polymer Engineering Division Evington Valley Road Leicester LE5 5 LY Telephone Leicester 730281 Aquafibre International Ltd Green Lane W...

Page 26: ...Broom 35 European Owners Manual Back Cover Original missing...

Reviews: