Brookstone Pure-Ion Bedroom User Manual Download Page 11

12

have been bent and touch each other.

•   If you find that the collection plates in the FILTER are not completely clean after 

one dishwasher cycle, increase the wash cycle time or wash them a second time.

•  It is safe to use standard dishwasher soap.
•   If hand washing, rinse the FILTER’s collection plates in your sink to remove loose 

debris. Submerge the entire FILTER in warm, soapy water and allow it to soak for 

15 minutes. Rinse with cold water.

•   You may use a small scrub brush to clean in between the collection plates, but 

take care not to bend them.

•   If you do not allow the FILTER to completely dry, you may hear a crackling noise 

during use. If this occurs, remove the FILTER and dry it completely before use.

USING THE DRYING MODE FUNCTION

IMPORTANT: The Drying Mode function should only be used to remove possible 
minor residual moisture. DO NOT use the Drying Mode to dry a soaking wet 
FILTER, as this may damage the unit.

1.   With the unit off and a clean FILTER in the unit, press and hold the FAN 

SPEED and TIMER buttons for 3 seconds. The unit will run the Fans on the 

Turbo setting with no electrical charge for 40 minutes. The Turbo Fan Speed  

LED will blink during the Drying Mode.

2.   After 40 minutes have passed, the unit will exit out of the Drying Mode and  

will turn off.

Note: To exit out of the Drying Mode before 40 minutes have passed, press the 
POWER button. The Drying Mode will be stopped and the unit will turn off.

9

USING THE AIR CLEANER AND HUMIDIFIER

POWERING THE UNIT ON/OFF

1.  Insert the power cord into an electrical outlet.

2.  Press the POWER button to turn the unit on.   illuminates.
3.  Press the POWER button to turn the unit off.

ADJUSTING THE CONTROL PANEL BRIGHTNESS

1.  The control panel has four brightness levels: High, Medium, Low and Off.

2.   To adjust the brightness level, press and hold the POWER button (when the  

unit is powered on) for 3 seconds. The control panel will cycle through  
the four brightness levels.

3.   Release the POWER button when the control panel displays your desired 

brightness level.

Note: If the brightness level is set to Medium, Low or Off, when any button is 
pressed, the brightness level will default to High for 5 seconds.

SELECTING AIR CLEANER FAN SPEED

Press the FAN SPEED button to choose between Whisper, Low, Medium, High and 

Turbo Fan Speeds. An LED will denote the selected Fan Speed.

Note: The FAN and the HUMIDIFIER can be used simultaneously or separately.

845680_I

N

S_Pure 

Ion 

Humidifier

5”W

x4.75”H_Output:100%_Prints:1/1,Blk

 

Summary of Contents for Pure-Ion Bedroom

Page 1: ...Pure IonBedroom AIR CLEANER HUMIDIFIER 845680_INS_Pure Ion Humidifier 5 Wx4 75 H_Output 100 _Prints 1 1 Blk Merrimack New Hampshire USA 03054 800 846 3000 www Brookstone com 845680...

Page 2: ...es used in conjunction with a covered product e a product or part that has been modified to alter functionality or capability f items intended to be periodically replaced by the purchaser during the n...

Page 3: ...the original product or 3 provide a store credit in the amount of the purchase price of the original product A replacement product or part including a user installable part installed in accordance wit...

Page 4: ...is unit on a level flat surface 10 Do not operate this unit on a table or desk Recommended for floor use only 11 Protect the power cord from being walked on or pinched particularly at plug outlets con...

Page 5: ...power source as indicated 16 Never block the air openings of the unit with materials such as clothing plastic bags or papers or place it on a soft surface such as a bed or couch where the air opening...

Page 6: ...o install the proper outlet Do not alter the plug in any way 4 845680_INS_Pure Ion Humidifier 5 Wx4 75 H_Output 100 _Prints 1 1 Blk 5 Carefully carry the BASE to a sink or bathtub and drain any remain...

Page 7: ...e MAIN HOUSING off the BASE 16 CAUTION This is not a medical device Small amounts of ozone are produced during the ionization process This unit complies with U S guidelines set for acceptable ozone em...

Page 8: ...nect from the electrical outlet 2 Lift and remove each WATER TANK from the unit 3 Lift and remove the FILTER from the unit 4 Press the RELEASE LATCHES on each side of the unit and lift the MAIN HOUSIN...

Page 9: ...th a clean cloth or paper towel Caution Do not rinse the BASE under running water Do not submerge the BASE in water Do not touch the ULTRASONIC DISK see Fig 1 with bare fingers as any fingerprints or...

Page 10: ...water in the WATER RESERVOIR Replace the WATER TANKS once the unit is on a level surface 845680_INS_Pure Ion Humidifier 5 Wx4 75 H_Output 100 _Prints 1 1 Blk 13 HUMIDIFIER MAINTENANCE IMPORTANT RISK O...

Page 11: ...Fan Speed LED will blink during the Drying Mode 2 After 40 minutes have passed the unit will exit out of the Drying Mode and will turn off Note To exit out of the Drying Mode before 40 minutes have p...

Page 12: ...collected on the FILTER s stainless steel collection plates If you see visible debris built up on the stainless steel collection plates please wash the FILTER The unit continues to clean the air when...

Reviews: