background image

2-3

Models 1350E and 1355E

Section 2 Installation

Installation and Operation Manual

X-VA-1350E-eng
Part Number: 541B082AAG
February, 2011

Figure 2-1 Typical Flowmeter Installation

A - Inlet Valve

B - Outlet Valve

C - Bypass Valve

D - Control Valve

E - Drain Valve

HORIZONTAL

LINE

D

A

E

C

VERTICAL

LINE

B

B

A

E

FLOWMETER

C

D

FLOWMETER

It is recommended that a final leak test of the system plumbing and meter
be performed before subjecting it to process fluid.
(See Section 4, Paragraph 4-2, e.)

2-5 Installation (See Figures 2-1, 2-2, 2-3, 2-4 and 2-5)

The flowmeter should be mounted within 6° of true vertical. The inlet
connection to the flowmeter is in the bottom end fitting. The connections
are normally horizontal, female NPT. Be sure the piping is adequately
supported to prevent undue strain on the meter.

Summary of Contents for Sho-Rate 1350E

Page 1: ...and Sho RateTM 150 Model 1355E Sizes 2 6 Model 1350E Sho Rate 50 With optional needle valve Model 1355E Sho Rate 150 With optional needle valve Model 1350E Sho Rate 50 With optional Integral flow controller Model 1355E Sho Rate 150 With optional Integral flow controller Model 1350E Sho Rate 50 no valve Model 1355E Sho Rate 150 no valve ...

Page 2: ... flow into the system Open process valves slowly to avoid flow surges 2 Check for leaks around the flow meter inlet and outlet connections If no leaks are present bring the system up to the operating pressure Please make sure that the process line pressure is removed prior to service When replacement parts are required ensure that qualified people use replacement parts specified by Brooks Instrume...

Page 3: ... and chemicals to medical devices analytical instrumentation semiconductor manufacturing and more The Brooks product you have just received is of the highest quality available offering superior performance reliability and value to the user It is designed with the ever changing process conditions accuracy requirements and hostile process environments in mind to provide you with a lifetime of depend...

Page 4: ...Models 1350E and 1355E Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Page 5: ...bly Cleaning 4 1 Section 5 Parts List Paragraph Page Number Number 5 1 General 5 1 Figures Figure Page Number Number 2 1 Typical Flowmeter Installation 2 3 2 2 Dimensions Sho Rate1350E 2 4 2 3 Dimensions Sho Rate1350E and 1355E with Integral Controller 2 5 2 4 Dimensions Sho Rate1355E 2 6 5 1 Parts Drawing Sho Rate Models 1350E and 1355E 5 2 Tables Table Page Number Number 1 1 Capacities for Sho R...

Page 6: ...ii Models 1350E and 1355E Contents Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Page 7: ... installation of the tube and float while the meter remains in the process piping 1 2 Specifications Capacities 1350 Series Refer to Tables 1 1 or 1 2 or 1 3 and 1 4 1355 Series Refer to Tables 1 3 and 1 4 or 1 5 Accuracy 1350 Series Standard Accuracy of 10 of full scale 1355 Series Standard 5 of full scale Repeatability 0 5 full scale Pressure Equipment Directive 97 23 EC Note Equipment falls und...

Page 8: ...arboloy tantalum Structural Members End fittings Chrome plated brass black anodized aluminum 316 stainless steel Side Plates Standard Black anodized aluminum Optional 316 stainless steel Window Clear polycarbonate Back Window Milk white polycarbonate Float Stops Standard Teflon Optional 316 Stainless Steel Tube Packing Standard Buna N Brass and aluminum meters Viton A fluoroelastomers 316 stainles...

Page 9: ...C5 R 6 65 A STN STL 5 50 ND1 20 0 ND3 26 0 NC9 650 ND2 CARBOLOY 8 50 NB2 32 0 NB3 36 0 NB5 950 NB6 TANTALUM 9 0 ND6 34 0 ND5 38 0 ND7 1000 ND4 6 GLASS 8 0 PB9 30 0 PB8 44 0 PC1 1100 PB7 SAPPHIRE 12 0 PC5 44 0 PC3 60 0 PC4 1500 PC2 R 6 65 B STN STL 19 0 PD1 70 0 PC9 85 0 PC8 2200 PC6 CARBOLOY 28 0 PB3 100 PB2 130 PB6 3400 PB4 TANTALUM 30 0 PD7 110 PD6 140 PD5 3600 PD4 FLOW RATES GIVEN ARE MAXIMUM V...

Page 10: ...omplete instruction manual go to our website BrooksInstrument com select Documentation Precision Valves Flow Controllers select FC8800 or FC8900 CODE MODEL 1350 TUBE MODEL 1355 TUBE A 1 65 R 2 15 A B 2 65A R 2 15 AA C 2 65B D R 2 15 AAA D 2 65C R 2 15 B E 3 65 R 2 15 C F 4 65 R 2 15 D G 5 65 R 6 15 A H 6 65 R 6 15 B J R 2 65 A K R 2 65 B L R 2 65 C M R 2 65 D N R 6 65 A P R 6 65 B Y NO TUBE NO TUB...

Page 11: ... GLASS 5 75 380 SCC M FA6 FA1 SAPPHIRE 10 5 518 SCC M FA8 FA3 2 R 2 15 D STN STL 20 6 832 SCC M FA7 FA2 CARBOLOY 33 2 1240 SCC M FA9 FA4 TANTALUM 35 9 1320 SCC M FB1 LIQ GAS FA5 GLASS 16 6 83 SLPM AA6 AB7 AC3 AA1 SAPPHIRE 26 3 1 1 SLPM AA8 AB9 AC4 AA3 R 2 15 A STN STL 46 2 1 69 SLPM AA7 AB8 AC6 AA2 CARBOLOY 70 8 2 44 SLPM AA9 AC1 AC5 AA4 TANTALUM 75 9 2 6 SLPM AB1 AC2 AC7 AA5 GLASS 52 8 2 37 SLPM ...

Page 12: ...1 6 Models 1350E and 1355E Section 1 Introduction Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Page 13: ... LLC Hatfield PA 19440 should be contacted to obtain a return shipment form Brooks Instrument 407 W Vine Street P O Box 903 Hatfield PA 19440 USA Toll Free 888 554 FLOW 3569 Tel 215 362 3700 Fax 215 362 3745 E mail BrooksAm BrooksInstrument com www BrooksInstrument com Brooks Instrument Brooks Instrument Neonstraat 3 1 4 4 Kitasuna Koto Ku 6718 WX Ede Netherlands Tokyo 136 0073 Japan P O Box 428 T...

Page 14: ... 3 5633 7100 6710 BK Ede Netherlands Fax 81 0 3 5633 7101 Tel 31 0 318 549 300 Email BrooksAs BrooksInstrument com Fax 31 0 318 549 309 E mail BrooksEu BrooksInstrument com 2 4 Recommended Storage Practice If intermediate or long term storage is required for equipment as supplied by Brooks Instrument it is recommended that said equipment be stored in accordance with the following a Within the orig...

Page 15: ...B A E FLOWMETER C D FLOWMETER It is recommended that a final leak test of the system plumbing and meter be performed before subjecting it to process fluid See Section 4 Paragraph 4 2 e 2 5 Installation See Figures 2 1 2 2 2 3 2 4 and 2 5 The flowmeter should be mounted within 6 of true vertical The inlet connection to the flowmeter is in the bottom end fitting The connections are normally horizont...

Page 16: ...ion Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 Model 1350E VB Valve Inlet with Aluminum Bezel Figure 2 2 Dimensions Sho Rate 1350E Model 1350E V Valve Inlet Cartridge Open Cartridge Open Inches Milimeters ...

Page 17: ... 62 41 1 1 91 48 5 1 4 Rc 1 81 46 0 1 91 48 5 3 8 Rc 2 09 53 1 2 35 59 7 1 00 25 4 F E 2 13 54 0 45 0 3 00 76 0 DET SCALE SHOWN OPTIONAL 1 25 31 8 32 8 0 36 0 MTG BRACKET R0TATABLE ADJUSTABLE SQ DIMENSIONS ARE INCH MM 2 HOLES A 1350 1355 SHO RATE 12 3 0 35 9 0 2 00 51 0 OUTLET CONN D B 1 38 35 0 32 8 0 INLET CONN 8800 FLOW CONTROLLER 50 12 7 1 12 28 6 1 42 36 0 1 77 MAX C 1 42 MIN REGULATING VALVE...

Page 18: ...llation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 Model 1355E VB Valve Inlet with Aluminum Bezel Figure 2 4 Dimensions Sho Rate 1355E Model 1355E V Valve Inlet 8 81 224 8 81 224 Cartridge Open Cartridge Open Inches Milimeters ...

Page 19: ...edle control valve may be provided to control the flow through the flowmeter These control valves are designed for fine control Excessive tightening may damage the valve seat and limit its effectiveness as a control valve If tight shut off is required it is recommended that a separate shut off valve should be installed in the line immediately before the flowmeter Flow indication is measured using ...

Page 20: ...3 2 Models 1350E and 1355E Section 3 Operation Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Page 21: ...4 1 Disassembly and Cleaning It is recommended the user periodically inspect the tube and float and clean if necessary Dirt or foreign materials adhering to the tube and float may cause inaccuracy and sticking of the float The metering tube Borosilicate glass and related parts may be cleaned with any solvent which does not attack glass ...

Page 22: ...4 2 Models 1350E and 1355E Section 4 Maintenance Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Page 23: ... List Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 5 1 General When ordering parts please specify Brooks Serial Number Model Number Part Number Description and Quantity Refer to Figure 5 1 and Table 5 1 ...

Page 24: ...5 2 Models 1350E and 1355E Section 5 Parts List Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 Figure 5 1 Parts Drawing Sho Rate Models 1350E and 1355E ...

Page 25: ...5 3 Models 1350E and 1355E Section 5 Parts List Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 Table 5 1 Parts List Sho Rate Models 1350E and 1355E ...

Page 26: ...is longer This limited warranty is the only warranty made by Seller and can be amended only in a writing signed by an authorized representative of Seller BROOKS SERVICE AND SUPPORT Brooks is committed to assuring all of our customers receive the ideal flow solution for their application along with outstanding service and support to back it up We operate first class repair facilities located around...

Reviews: