1-1
Models 1350E and 1355E
Section 1 Introduction
Installation and Operation Manual
X-VA-1350E-eng
Part Number: 541B082AAG
February, 2011
1-1 Description
The Sho-Rate Flowmeters are variable area, glass tube, flow rate
indicating meters. The basic elements are a tapered glass metering tube
and a metering float. Features include quick and simple removal or
installation of the tube and float while the meter remains in the process
piping.
1-2 Specifications
Capacities
1350 Series: Refer to Tables 1-1 or 1-2, or 1-3 and 1-4
1355 Series: Refer to Tables 1-3 and 1-4, or 1-5
Accuracy
1350 Series Standard: Accuracy of ±10% of full scale
1355 Series Standard: ±5% of full scale
Repeatability
0.5% full scale
Pressure Equipment Directive (97/23/EC)
Note: Equipment falls under Sound Engineering Practice (SEP) according
to the directive.
Pressure/Temperature
200 psig at temperatures 33°F to 250°F
Pressure Drop
Inquire at factory