background image

Brooks Automation

FluidX

Part Number: 281947 Rev. C

2. Installation

The system has been designed with minimal user setup 
and no software is required, the USB connector cable is 
already fitted.

Step

Action

1.  

Ensure the connector cable is fully inserted into 
the Scope reader, then connect the USB end to 
the USB port on the host device to power up the 
reader.

2.  

The unit will beep twice and the LED will turn off. 
The Scope USB is now ready for use.

 

NOTE: 

Any 2D Coded Tube scanned will 

be sent directly through the keyboard 
buffer to wherever the cursor is blinking.

2

Copyright © 2020, Brooks Automation, Inc.

Summary of Contents for FluidX Scope USB

Page 1: ...FluidX Scope USB User Manual Part Number 281947 Rev C...

Page 2: ...pCooler TopLigner Tube Auditor Ultimate Blue VAC 407 VacuTran VersaPort and WaferEngine are trademarks of Brooks Automation Inc AcuTran AquaTrap Asyst the Cool Solutions logo Crossing Automation Cryod...

Page 3: ...364 176 9999 6 Has Toll http www brooks com Japan 81 120 255 390 Toll Free 81 45 330 9005 Local http jp brooks com China 86 400 627 6657 http cn brooks com Taiwan 886 080 003 5556 Toll Free 886 3 5525...

Page 4: ...e Science Systems BioStorage Technologies 2910 Fortune Circle West Suite E Indianapolis IN 46241 Tel 1 317 268 5500 Fax 1 317 390 1868 Brooks Automation Israel Ltd Mevo Yerach 5 Kiryat Gat 82000 Israe...

Page 5: ...23 D 01109 Dresden Germany Tel 49 351 885 930 Fax 49 351 885 9322 Brooks Japan K K YOKKAICHI SERVICE CENTER Hikari Shokai Yokkaichi Bldg 2 26 Shinshinmachi Yokkaichi Mie 510 0094 Tel 81 59 359 5611 Fa...

Page 6: ...5 No 32 Tai Yuen Street Chu Pei City Hsinchu County 302 Taiwan R O C Tel 886 3 552 5258 Fax G A 886 3 552 5255 Fax Sales 886 3 552 5200 Brooks Automation Korea Inc 35 Giheungdanji Ro 121Beon Gil Giheu...

Page 7: ...ion 5 07 2014 Initial completion of the manual Revision A 95874 4 25 2017 Image Updates Revision B EC107106 10 1 2018 Brooks Re Branding and application of Brooks Templates Revision C EC118417 3 12 20...

Page 8: ...tion 1 2 Installation 2 3 Attaching the Cable 3 4 Detaching the Cable 5 5 Reading a Tube 7 6 Reading a Linear Barcode 9 7 Reader Feedback 10 8 Quick Setup Codes 11 9 Preventative Maintenance 14 Append...

Page 9: ...code reader It is capable of reading standard pre coded tubes from a range of manufacturers assuming they adhere to the ISO 16022 Data Matrix Two Dimensional Bar Code format The Scope USB can also re...

Page 10: ...on 1 Ensure the connector cable is fully inserted into the Scope reader then connect the USB end to the USB port on the host device to power up the reader 2 The unit will beep twice and the LED will t...

Page 11: ...3 Attaching the Cable The RJ50 cable is a multi pin connector and can be damaged if handled incorrectly Ensure that the cable is fully pushed home Errors may occur if the cable is not properly instal...

Page 12: ...1947 Rev C Step Action 1 The connector cable is already attached but if necessary the cable can be inserted by slotting the RJ50 connector into the reader NOTE Ensure it is in the correct orientation...

Page 13: ...t Number 281947 Rev C 4 Detaching the Cable Detaching a cable from the FluidX Scope USB is simple Step Action 1 Insert one end of a paperclip into the hole on the back of the reader Copyright 2020 Bro...

Page 14: ...Brooks Automation FluidX Part Number 281947 Rev C Step Action 2 Apply pressure on the paperclip and gently pull the cable from the reader 6 Copyright 2020 Brooks Automation Inc...

Page 15: ...ing mode so the button will need to be pressed to scan Step Action 1 Hold the tube approximately 0 5 cm 0 2 in from the scanning window and then press the button on top of the reader NOTE This will pr...

Page 16: ...ON Quick Setup Code on Page 11 If the continuous scan has been enabled use the following instructions Step Action 1 Hold the tube approximately 0 5 cm 0 2 in from the scanning window NOTE This will pr...

Page 17: ...near Barcode The FluidX Scope USB also reads linear barcodes Step Action 1 Use the targeting light to aim the beam over the linear barcode and press the read button The unit will beep once to indicate...

Page 18: ...Feedback Audio Feedback Successfully powers up Green LED lights up 2 Beeps Attempting to decode Green LED light is off None Successful decode and data transfer via cable Green LED lights up 1 Beep Co...

Page 19: ...e USB can be configured by scanning one of the codes from the table below NOTE The configuration change will take effect immediately and be saved to memory Action Setup Code Setting Continuous Scan Of...

Page 20: ...ive OS Default Enable Alternative OS MAC Linux Optional Enabled reading of reversed codes black on white or white on black Default French Keyboard Mapping Optional German Keyboard Mapping Optional Jap...

Page 21: ...281947 Rev C Action Setup Code Setting Reader ID and Firmware Technical Support STD Contrast Code 35 AGC Optional Suffix Enter Default Suffix Tab Optional Universal Keyboard Mapping Default Copyright...

Page 22: ...riodically clean the scanning window with a moist non abrasive cloth to allow the best performance of the device The following are safe to use for cleaning as needed l IPA Isopropyl Alcohol l 70 alcoh...

Page 23: ...Brooks Automation Part Number 281947 Rev C Appendix A Declaration of CE Conformity Copyright 2020 Brooks Automation Inc 15...