Site Manual
Alarm 2000 Iss 5
58
DATE
ISS
REVISION
ORIGINAL ISSUE
DRN CHK
TITLE
DRAWN
PART No.
DRAWING No.
A.S.
CHECKED
ISSUE
No.
SUB700
21/11/00
21/11/00
O.P.
A.S.
O.P.
SH 1 of 6
F565-A
ALARM
BGA IN
AUX 24V
SYSTEM OFF
ALARM
FAULT
LK1
MO
COM
+
-
+
I
N
A
+
+
+
+
+
+
+
N
A
+
S
e
ri
a
l N
o
P
C
B
1
7
6
R
1
S
U
B
7
0
0
R3
R
L
2
R1
TB4
TH1
D17
C1
Q4
RP1
RP2
RP3
C9
C10
C
1
1
R16
R17
R21
Q9
R19
R18
D4
D3
D2
F3
F2
M10
M9
M8
M7
M6
M5
M4
F4
RL4
R
L
5
RL3
RL1
TB6
T
B
7
F1
U2
R
L
6
M1
M3
R2
Q2
Q3
R6
R7
C2
D
1
3
Q1
C3
SW1
6
5
1 2 3 4
U1
555
D6
D14
D9
C8
C7
R
1
2
R15 R14
R13
R11
C12
C4
R8
R9
R10
C6
Q8
U4
Q10
D8
R5
R4
Q7
D10
D11
R
2
0
D1
U3
LM324
J2
D5
D
1
5
D7
C5
Q6
D
1
2
D
1
6
T
B
5
D18
B
R
O
O
K
S
R
2
2
ZD1
Q5
TB3
+ 24V -
B+
B-
+
-
+
-
PANIC
N/O
N/C
COM N/O
N/C
N/C
N/O
COM
0V
COM+
Vout
- 2
4
V
+
FL
SF
FT
A
L
o
A
L
i
A
N1
N2
I
M2
RL7
TB1
TB2
+
-
ALARM IN
ALARM OUT
FAULT
PSU FAULT
FLASH BUS
TO SMOKE
ALARMS
WITHOUT
ISOLATOR
TO SMOKE
ALARMS
ISOLATOR
WITH
P
A
N
IC
I
N
P
U
T
B
G
A
I
N
(
N
/O
)
A
U
X
.
2
4
V
S
Y
S
T
E
M
O
F
F
D
R
Y
C
O
N
T
A
C
T
C
O
M
.
F
A
U
L
T
D
R
Y
C
O
N
T
A
C
T
A
L
A
R
M
O
U
T
P
U
T
A
L
A
R
M
O
U
T
P
U
T
2
4
V
D
C
/1
A
240V
IN
BROOKS
AUSTRALIA
13/3/2002
1
A.S.
O.P.
MAINS ON
24V IN
TO KEY SWITCH
ALARM 2000 RESIDENTIAL PANEL
MAIN CONTROL BOARD
DATA SHEET
OUTPUTS : 240V AC to connect Smoke/Heat Alarms with Alarm Isolator, TB1
240V AC to connect Smoke/Heat Alarms without Alarm Isolator, TB2
ON
ON
OFF
ON
OFF
ON
ON
ON
OFF
ON
OFF
ON
ON
ON
S5
S6
S2
S1
S3
S4
Fire Mone activates 24V DC BGA output
Both Smoke/Heat Alarms and BGA input activate alarm dry contact output
Both Smoke/Heat Alarms and BGA input activate Optional Modules
BGA input initiate Fire Mode
Only BGA input activates alarm dry contact output
Only Smoke/Heat Alarms activate alarm dry contact output
Only BGA input activate Optional Modules
Only Smoke/Heat Alarms activates Optional Modules
Alarm Isolator Switch : To isolate activated Smoke/Heat Alarms for 5 minutes
MCP Input Fault LED : Steady Amber
Power Supply Fault LED : Steady Amber
Mains ON LED : Green
Alarm Activated LED : Flashing Red
System OFF LED : Flashing Red
Alarm Output Fault LED : Steady Amber
Alarm Locator Switch : Locate the activated Smoke/Heat Alarm with built in Amber LED which illuminates during locate timing
CONTROLS & INDICATORS (on Display Board) :
DIP Switch Setting
DESCRIPTION : ALARM 2000 Main Control and Termination Board provides the necessary control, monitoring and
termination of Mains Smoke / Heat Alarms and Manual Call Points.
120 mA Maximum alarm current including MCP activation
SPECIFICATIONS : Operational Voltage : 24V DC
Current Consumption : 20 mA Quiecent
INPUTS : 240V AC to supply power to Smoke/ Heat Alarms, TB3
Monitored Manual Call Point input, EOL Resistor is 3K3, TB6
Panic input (normally open contact) to activate Smoke/Heat alarms and/or Manual Call Point output, TB6
Monitored 24V DC alarm output, EOL resistor 3K3, TB6
Voltage free contact alarm output, TB6
Voltage free contact fault output, TB6
Voltage free contact System OFF, TB6
Auxillary fused 24V DC @ 1A for other applications, TB6
Fault Sounder Sielence Switch : Mute sounder with built in Amber LED
FUSES : F1 = 3A F2 = 1A
F3 = 1A F4 = 1.5A
ALL FUSES ARE FAST BLOW & 1 AG
UPDATE TO Vcad
20/8/2002
2
A.S.
O.P.
2
21/11/2000
0
ADD FUSE FUNCTION, RATING & TYPE
-
+
Summary of Contents for ALARM 2000
Page 1: ...SITE MANUAL Issue 5 ALARM 2000 Residential Fire System MA260 November 2017...
Page 40: ...Site Manual Alarm 2000 Iss 5 40 Charger low 26 5V Battery low 23 8V Battery fail 21 0V...
Page 42: ...Site Manual Alarm 2000 Iss 5 42 7 Location and type of smoke heat alarms Location Type Model...
Page 43: ...Site Manual Alarm 2000 Iss 5 43 8 Location and type of ancillary equipment Location Type Model...
Page 63: ...Site Manual Alarm 2000 Iss 5 63...
Page 64: ...Site Manual Alarm 2000 Iss 5 64...
Page 65: ...Site Manual Alarm 2000 Iss 5 65...