Connections: 
Seatalk signal wire (yellow) 

 ST Yellow Signal 

Seatalk shield (-12V) 

     

 ST  Shld – 

S12V (red)              

 ST  Red + 

Note: If the Seatalk option has been ordered, it has been enabled in our workshop. This means 
that CH1 NMEA IN cannot be used for a NMEA  talker connection. 
To disable Seatalk and free up CH1 for NMEA, the setup procedure has to be executed.  
 

NMEA Listeners (4800 baud): 

Note that the 4800 bps multiplexer output is the baudrate conversion output and by default not 
the combined output of the connected NMEA talkers. Also refer to “Baudrate Conversion options” 
below. 
 
NMEA Input A +  

 

  Grey connector top screw (NMEA OUT + 4800 baud) 

NMEA Input B -  

 

  Grey connector bottom screw (NMEA OUT – 4800 baud) 

 
A maximum of 4 NMEA listeners can be connected in parallel to this output, provided that they 
comply with the NMEA standard. The output is a differential signal (RS422, NMEA standard). The 
top screw terminal is A, the bottom B.  
  

C- or E-series: 

Assuming Raymarine NMEA cable R08004, connect as follows: 
(NMEA baudrate in C- or E- series has to be set to 38400 - AIS) 
 
NMEA  (Yellow)  

 

  As indicated on mux    

NMEA Output -  (Brown)  

 

  As indicated on mux 

NMEA Input +  (White)  

 

  As indicated on mux 

NMEA Input -   (Green)  

 

  As indicated on mux 

 

 

 
Note: This is the standard wiring method. The baudrate of the NMEA output from the C- or E-
series is converted by the mux from 38400 to 4800 bps, allowing connection of standard NMEA 
listeners to the 4800 bps output on the mux (grey connector) to receive NMEA data from the C- or 
E-series. There are alternative wiring methods whereby instead of the C-/E-series NMEA output, 
the computer output is converted to 4800 bps, e.g. to control the auto pilot in track-mode or to be 
able to load waypoints/routes from the computer to the C-/E-series chartplotter. 
 

RS232 output 

The output of  multiplexer model AIS-C can also be connected to a serial computer port. 
Assuming a 9-pin D-sub connector, mux terminal TxD should be connected to pin 2 of the 
computer connector and the G-terminal (labelled “Brown C-series NMEA  out –“) to pin 5. If the 
standard wiring method is used, this means that the brown wire of the the C-/E- series cable and 
the pin 5 wire of the RS232 port are combined in the same terminal   

 
USB 

The USB connection is optional and is only required if the output of the mux AIS-C also needs to 
be connected to a computer. Follow the instructions in the standard multiplexer manual for USB 
driver installation. 
 
 

Alternative use of the baudrate conversion feature 

In the standard connection method, described above, the baud rate of NMEA data received from 
the C- or E-series chart plotter at 38400 bps is converted to 4800bps. If a computer is part of the 
integrated system, the baudrate conversion feature may be used in a different way, in particular if 
the multiplexer Seatalk-NMEA conversion option has been installed. In the latter case, data from 
the Seatalk network, including GPS data, is already converted to NMEA by the multiplexer and 
the system is not dependent on NMEA data output by the chart plotter. 