16
8.2
Set charging dimmer (dim)
The dim function can be switched on or off (on/--) by briefly pressing the “up/down” key
(17) of lamp base outlet 2. If the dim function is switched on, the modelling light will
extinguish when charging takes place. This feature can be used as a visual flash
monitor and to reduce the current load on weak mains (AC-lines).
8.3
Set slow charge (slow)
In case of weak mains (AC-line) power supply lines, charging time may be extended to
approx. double the standard value. The slow charge mode is switched on or off (on/--)
by briefly pressing the “up/down” key (17) of the lamp base outlet 2.
8.4
Set buzzer (buz)
The ready buzzer sounds when the power capacitors are 100% charged up. The ready
buzzer is switched on or off (on/--) by briefly pressing the “up/down” key (17) of the lamp
base outlet 2. The alarm tone will remain audible even if the ready buzzer is switched
off.
8.5 Sequences
(serial
flashes)
This function is selected with a prolonged pressure (1 s) on the key “test” and it permits
to set a defined number of flash discharges from 1 to 8 (displays “n1” to “n8”). When the
function is activated, i.e. a value between “n1” and “n8” is selected, the digital display
no. 1 (15) shows alternately the selected value of flash energy and the sequence of
flashes. The function is de-activated by selecting the value “n0”. Returning to the former
operating mode, is effected by pressing the key “aux” (8).
9. Basic settings ex works
The basic settings ex works can be viewed and in some instances changed with the
following procedure:
Switch the unit on. Simultaneously press the "mod" (7) and "aux" (8) keys for 5
seconds. Digital display 2 (15) shows the selected function number and digital display 1
(15) shows the actual setting. Both values can be changed with the "up"/"down" key
(17).