15
7.2
The audible signal
("buzzer") sounds when the power capacitors are at 100% charge of the set flash
energy. It may be switched on or off (chapter 8).
7.3
Audible fault signal
When the flash discharge fails, a warning signal of approx. 3s duration will sound and
the display (15) of the respective lamp base will blink.
8. Setting additional functions
The "aux" key (8) is used to select additional functions. Repeated actuation of the key
toggles through the following display modes:
- Select proportionality level of the modelling light
LED “prop” blinks (13)
- Set DIM
LED “dim” blinks (12)
- Set slow charging
LED “slow” blinks (11)
- Set buzzer
LED “buz” blinks (10)
- Return to standard display
no LED blinks
After the setting has been performed, the standard display can be re-activated by
pressing the „aux“ key (8) or automatically after a waiting time of 4 seconds.
To set the additional functions select the respective LED (example: "Set dim"). The
digital display 2 (15) will then show the actual value which can be changed with the
"up/down" key (17). If a setting is entered which deviates from the basic setting value,
the respective LED will remain lit as a reminder after the display returns to standard
(exception: function „prop“). If the unit is switched off and on again, it will be in the
"standard display" mode. Previously set additional functions are retained.
8.1
Set proportionality level of the modelling light (prop)
The proportionality level of the modelling light can be selected by a brief pressure on the
"up/down" key (17) of the lamp base switch 2. With repeated actuation of the key the
following modes can be set, each shown respectively on the digital display 2 (15): P1,
P2, P3, P4, P5, HI, LO.