10
7. Protecting glass
For safety reasons the lamp base HMI F575.800 can only be operated with a mounted
protecting glass and is equipped with a circuit breaker. Therefore the unit cannot be
switched on without a protecting glass. The UV-coated protecting glass is also available
in a matt version.
8. Fuses
The fuses (10 and 11) are located on the operating side of the ballast unit HMI 575.800.
Use exclusively sand filled fuses with the value 10 AT. The use of wrong fuses can
cause extensive damage to the ballast unit or lamp base.
9. Mounting
The stand adapter is located underneath the housing. It allows the insertion of 12 mm
(broncolor
®
) or 16 mm bolts.
When operating make sure that the unit is securely fixed on the stand. By pulling out the
stop lever it can adjusted in its notches.
10. Service/repair
Your broncolor daylight source is a precision unit. If you take good care, it will work
trouble-free for many years. However, if you should have any failures, please, do not try
to open the unit to repair it yourself. Even if the unit is switched off, dangerous voltages
can remain within the unit. Therefore, always leave servicing and repairs to a broncolor
service agency.