Bromic Heating COBALT SMART-HEAT 2000W Installation, Instruction And  Service Manual Download Page 9

9

www.bromicheating.com

 31 

 575 

 625 

2000W & 4000W Models

Mounting Hole Centres & Heater Position

1

 31 

 918 

 868 

3000W & 6000W Models

  

2

Suspension

 20 

 10 

  6.5 

DETAIL Suspension 

SCALE 1 : 5

Suspension Tube

Mounting Hole

3

4

6

7

5

8

9

1. Mark mounting hole centres on ceiling.

    Attach mounting brackets to ceiling using 

    appropriate fasteners (Not supplied).

2. Heater must be installed with heater surface at least

2400mm above the floor level.

Supplied suspension tubes position heater surface

1000mm below the ceiling surface.

If required, cut down length of suspension tubes to

ensure correct installation height.

Minimum distance from front surface of heater to

ceiling surface must be 250mm for 2000W & 3000W 

models & 330mm for 4000W & 6000W models. 

3. If suspension tubes are cut down, drill new mounting

holes in each tube.

4. Make electrical connection in junction box as per 

electrical installation instructions in this manual.
5. Feed power cord through suspension tube.
6. Assemble suspension tubes to rear bracket with M5

screw, spring washer and nut.
7. Rotate heater to required angle. 15° or 30° in either

direction. Lock into position with self tapping screw.
8. Raise heater assembly into position.

Attach suspension tubes to ceiling brackets with 

M5x35mm screws, spring washers & nuts.

9. Make electrical connection from suspension tube 

power cord to power from ceiling as per 

electrical installation instructions in this manual.

TUBE SUSPENSION (SOLD SEPARATELY)

 TUBE SUSPENSION 

(SOLD SEPARATELY)

1.  Mark mounting hole centres on ceiling. Attach 

mounting brackets to ceiling using appropriate 

fasteners (Not supplied). 

2.  Heater must be installed with heater surface at least 

2400mm above the floor level. Supplied suspension 

tubes position heater surface 39.4” below the ceiling 

surface. If required, cut down length of suspension 

tubes to ensure correct installation height. Minimum 

distance from front surface of heater to ceiling surface 

must be 9.8” for 2000W & 3000W models & 330mm for 

4000W & 6000W models. 

3.  If suspension tubes are cut down, drill new mounting 

holes in each tube.

4.  Make electrical connection in junction box as per 

electrical installation instructions in this manual.

5.  Feed power cord through suspension tube.
6.  Assemble suspension tubes to rear bracket with M5 

screw, spring washer and nut.

7.  Rotate heater to required angle. 15° or 30° in either 

direction. Lock into position with self tapping screw. 

8.  Raise heater assembly into position. Attach 

suspension tubes to ceiling brackets with M5x35mm 

screws, spring washers & nuts.

9.  Make electrical connection from suspension tube 

power cord to power from ceiling as per electrical 

installation instructions in this manual.

HEATER INSTALLATION 

CONTINUED...

Summary of Contents for COBALT SMART-HEAT 2000W

Page 1: ...OUT THIS MANUAL KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFERENCE COBALT SMART HEAT ELECTRIC HEATER BY BROMIC INSTALLATION INSTRUCTION AND SERVICE MANUAL SUITABLE FOR ELECTRIC HEATER MODELS COBALT...

Page 2: ...of of leaving the room on their own unless constant supervision is provided Patent Pending Australian Registered Design 338721 BROMIC HEATING Head Office 10 Phiney Place Ingleburn NSW 2565 Australia T...

Page 3: ...URES 5 SPECIFICATIONS 5 HEATER INSTALLATION 6 REMOVE PACKAGING MATERIAL 6 INSTALLATION CLEARANCES 7 CEILING WALL MOUNTING 8 CHAIN SUSPENSION 8 TUBE SUSPENSION 9 ELECTRICAL INSTALLATION 10 WIRING DIAGR...

Page 4: ...eater in an explosive environment such as areas where petrol or other flammable liquids or vapours are stored Clothing or other flammable materials should not be hung from the heater or placed on or n...

Page 5: ...waste disposal service or the place of purchase PRODUCT OVERVIEW IMPORTANT NOTES AND WARNINGS CONTINUES PRODUCT FEATURES The Cobalt Smart Heat Electric heaters are designed to provide efficient spot h...

Page 6: ...e cover by pulling it out from under the edge of the heater and in between the reflector 3 Remove packing material around heating elements 4 Check element markings at both ends of heater Ensure marks...

Page 7: ...NTING MINIMUM CLEARANCE TO FLOOR 1800 96 8 WALL MOUNTING MINIMUM CLEARANCE TO FLOOR 1800 96 8 WALL MOUNTING MINIMUM CLEARANCE TO FLOOR 3 0 150 110 10 12 12 5 12 13 18 12 4 6 250 300 300 45 120 4 5 240...

Page 8: ...x suply power cord to ceiling chain with cable ties Mounting Hole Centres Heater Position 2620213 3000W 2620215 6000W 2620212 2000W 2620214 4000W 1 CEILING WALL MOUNTING 1 Mark mounting hole centres...

Page 9: ...ts 9 Make electrical connection from suspension tube power cord to power from ceiling as per electrical installation instructions in this manual TUBE SUSPENSION SOLD SEPARATELY TUBE SUSPENSION SOLD SE...

Page 10: ...y before installing or servicing this heater Read and follow installation clearance requirements outlined in this manual The Appliance MUST be connected to a properly grounded electrical source Discon...

Page 11: ...permanently installed and hard wired by an authorised licenced person Junction Box AC Heater Element 1 240 V AC SINGLE PHASE EARTH WIRE Heater Element 2 WIRING DIAGRAM COBALT SMART HEAT ELECTRIC OPTIO...

Page 12: ...may occur Disconnect from electrical supply before servicing this heater WARNING Servicing and maintenance MUST be carried out by an authorised and licensed person only 1 Remove the wire cover by pull...

Page 13: ...ersists TROUBLESHOOTING Version 1 1GB Revised 30 07 2015 No Description PART NUMBER 1 Heater Cobalt electric 2000W 240V EU BH0610005 2 Heater Cobalt electric 3000W 240V EU BH0610006 3 Heater Cobalt el...

Reviews: