Bromic Heating COBALT SMART-HEAT 2000W Installation, Instruction And  Service Manual Download Page 13

13

www.bromicheating.com

REPLACEMENT PART LIST

SYMPTOM

POSSIBLE CAUSE (S)

CORRECTIVE ACTION

Element does not energize

1. Defective element

2. Improper connection

1. Replace element

2. Check connection to power 

outlet

Not enough heat

1. Heater too small for application

2. Heater mounted too high or too 

far

1. Add additional heater(s)

2. Decrease mounting height or 

distance

Too much heat

1. Heater too large for application

2. Heater mount too low or too close

1. Replace with smaller heater

2. Increase mounting height or 

distance

Hot spot in Tube

1. Heater is not level

2. Grease or moisture on tube

1. Adjust to level mount

2. Clear tube-replace if problem 

persists

TROUBLESHOOTING

Version 1.1GB

Revised: 30/07/2015

No.

Description

PART NUMBER

1

Heater - Cobalt electric 2000W 240V - EU

BH0610005

2

Heater - Cobalt electric 3000W 240V - EU

BH0610006

3

Heater - Cobalt electric 4000W 240V - EU

BH0610007

4

Heater - Cobalt electric 6000W 240V - EU

BH0610008

5

Front cover  - Cobalt electric 2000W & 4000W 

BH8180030

6

Front cover  - Cobalt electric 3000W & 6000W 

BH8180031

7

Element end cover set  - Cobalt electric 2000W & 3000W 

BH8180032

8

Element end cover set  - Cobalt electric 4000W & 6000W 

BH8180033

9

Junction box cover & seal set - Cobalt electric 

BH8180034

10

Mounting Bracket set (short) - Cobalt electric 

BH8180035

11

Mounting Bracket set (Long) - Cobalt electric 

BH8180036

12

Ceiling recess kit  - Cobalt electric 2000W & 4000W 

BH3130014

13

Ceiling recess kit  - Cobalt electric 3000W & 6000W 

BH3130015

14

Tube suspension kit - Cobalt electric 

BH3130016

Summary of Contents for COBALT SMART-HEAT 2000W

Page 1: ...OUT THIS MANUAL KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFERENCE COBALT SMART HEAT ELECTRIC HEATER BY BROMIC INSTALLATION INSTRUCTION AND SERVICE MANUAL SUITABLE FOR ELECTRIC HEATER MODELS COBALT...

Page 2: ...of of leaving the room on their own unless constant supervision is provided Patent Pending Australian Registered Design 338721 BROMIC HEATING Head Office 10 Phiney Place Ingleburn NSW 2565 Australia T...

Page 3: ...URES 5 SPECIFICATIONS 5 HEATER INSTALLATION 6 REMOVE PACKAGING MATERIAL 6 INSTALLATION CLEARANCES 7 CEILING WALL MOUNTING 8 CHAIN SUSPENSION 8 TUBE SUSPENSION 9 ELECTRICAL INSTALLATION 10 WIRING DIAGR...

Page 4: ...eater in an explosive environment such as areas where petrol or other flammable liquids or vapours are stored Clothing or other flammable materials should not be hung from the heater or placed on or n...

Page 5: ...waste disposal service or the place of purchase PRODUCT OVERVIEW IMPORTANT NOTES AND WARNINGS CONTINUES PRODUCT FEATURES The Cobalt Smart Heat Electric heaters are designed to provide efficient spot h...

Page 6: ...e cover by pulling it out from under the edge of the heater and in between the reflector 3 Remove packing material around heating elements 4 Check element markings at both ends of heater Ensure marks...

Page 7: ...NTING MINIMUM CLEARANCE TO FLOOR 1800 96 8 WALL MOUNTING MINIMUM CLEARANCE TO FLOOR 1800 96 8 WALL MOUNTING MINIMUM CLEARANCE TO FLOOR 3 0 150 110 10 12 12 5 12 13 18 12 4 6 250 300 300 45 120 4 5 240...

Page 8: ...x suply power cord to ceiling chain with cable ties Mounting Hole Centres Heater Position 2620213 3000W 2620215 6000W 2620212 2000W 2620214 4000W 1 CEILING WALL MOUNTING 1 Mark mounting hole centres...

Page 9: ...ts 9 Make electrical connection from suspension tube power cord to power from ceiling as per electrical installation instructions in this manual TUBE SUSPENSION SOLD SEPARATELY TUBE SUSPENSION SOLD SE...

Page 10: ...y before installing or servicing this heater Read and follow installation clearance requirements outlined in this manual The Appliance MUST be connected to a properly grounded electrical source Discon...

Page 11: ...permanently installed and hard wired by an authorised licenced person Junction Box AC Heater Element 1 240 V AC SINGLE PHASE EARTH WIRE Heater Element 2 WIRING DIAGRAM COBALT SMART HEAT ELECTRIC OPTIO...

Page 12: ...may occur Disconnect from electrical supply before servicing this heater WARNING Servicing and maintenance MUST be carried out by an authorised and licensed person only 1 Remove the wire cover by pull...

Page 13: ...ersists TROUBLESHOOTING Version 1 1GB Revised 30 07 2015 No Description PART NUMBER 1 Heater Cobalt electric 2000W 240V EU BH0610005 2 Heater Cobalt electric 3000W 240V EU BH0610006 3 Heater Cobalt el...

Reviews: