6
bromic.com/heating
HEATING INSTALLATION INSTRUCTIONS
PRODUCT FEATURES
This heater MUST be permanently installed by
an authorised/licenced person. Do not perform
maintenance, or carry out installation or assembly
procedure while electrical power is switched on. Wait
2 hours after switching off the heater before handling.
!
!
Ensure that the heating unit is not directly
exposed to rain or water contact. For longest
product life and to maintain product appearance,
mount heater under cover and protect from rain
and weather.
WARNING - Outdoor Installation
WARNING - Outdoor Installation
CEILING & WALL MOUNTING
•
Heaters must be away from the fourth wall.
!
!
•
Heaters must be installed according to the
minimum installation clearances shown in these
diagrams
.
WALL MOUNTING
CEILING
FLOOR
CEILING MOUNTING
(FACE DOWN)
CEILING
FLOOR
CEILING MOUNTING
CEILING
FLOOR
CEILING MOUNTING
(ANGLED)
CEILING
FLOOR
84.5”
6”
6.5”
72” (6’)
104”
8”
10” (2300w Model)
18” (3400w Model)
96” (8’)
106”
10”
96” (8’)
12”
96” (8’)
8”
12”
104”
MINIMUM DISTANCE BETWEEN
HEATERS MEASURED FROM EDGE
OF HEATER MUST BE AT LEAST 20"
!!
WARNING
!!