Bromic Heating BH0320003 Installation, Instruction And  Service Manual Download Page 5

5

bromic.com/heating

service technician if you are unsure if you have a circuit breaker 
installed on the premises.

• Do not install the heater directly near a bathtub, shower or
swimming pool. Any switches or controls must not be within
reach of a person in the bathtub, shower or swimming pool.

• To maintain Ingress Protection Rating (IPX4), only IP44 rated
conduit fittings should be used for electrical installation.

• A means for disconnection of the heater must be
incorporated in the fixed wiring according to the local
electrical codes.

• If the supply cord is damaged, it must be replaced by an
authorised and licenced person in order to avoid a hazard.

• Do not bend the electrical connection to the power supply.

• Keep the cable away from sharp edges during handling and
installation.

• Do not pull on the cable or subject it to traction force.

• Avoid physical shock & impact to the heater when handling.

• Do not apply any pressure on the glass surface.

• Keep the electrical connection area to the power supply
clean.

• Ensure that the heating unit is not directly exposed to rain or
water contact.

• Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.

• If any part of the instruction manual is missing or damaged,
contact Bromic for a complete version.

• If you are unsure of any aspect of the installation, contact
Bromic for advice.

The Platinum Smart-Heat™ Electric is designed to provide efficient spot heating for commercial and 
residential applications. 

The heaters are built with corrosion resistant materials, have electrical approval in North America and are 
rated to IPX4 water Ingress Protection. Making the Platinum Smart-Heat™ Electric the perfect solution for a 
variety of indoor and outdoor heating applications.

PRODUCT OVERVIEW

IMPORTANT NOTES AND WARNINGS 

CONTINUED

 ...

PRODUCT FEATURES

Ultra-thin and stylish design

Efficient directional spot heating

Heat Zones — one or more heaters can be switched
on and off simultaneously from a single remote-
located switch

Platinum Smart-Heat™ Electric Heaters

 can also be

integrated into smart control systems

Wind resistant & IPX4 water protection rating

Suitable for outdoor and indoor heating applications
such as restaurants, cafes, bars and clubs, factories,
office spaces, designated smoking areas, public
areas, hotels and more

Standard Mounting - included with heater

Optional Mounting - purchased separately from
heater:

Ceiling Recess

Tube Suspension

SPECIFICATIONS

Model

Platinum Smart-Heat™ Electric II

Part no.

BH0320003

BH0320005

BH0320007

BH0320008

Heat Output (Watts)

2300W

3400W

Power connection required (Volts/Amps)

220-240V - A.C.

- 50/60Hz - 9.6A

220-240V - A.C. -

50/60Hz - 14.2A

Dimensions (WxHxDmm)

840 x 182 x 54 mm 

(33.0 x 7.0 x 2.0”)

1275 x 182 x 54 mm

(50.2 x 7.0 x 2.0”)

Weight (kg)

7.5kg (16.5lbs)

10kg (22lbs)

Finish

Brushed Stainless Steel 304

Approval 

Intertek: 5001799

Black

White

Summary of Contents for BH0320003

Page 1: ...BY BROMIC INSTALLATION INSTRUCTION AND SERVICE MANUAL IMPORTANT READ THIS MANUAL CAREFULLY SEE INSIDE COVER FOR IMPORTANT INFORMATION ABOUT THIS MANUAL KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFE...

Page 2: ...RNING IMPORTANT READ THIS MANUAL CAREFULLY before installing or servicing this product Improper installation operation or maintenance can result in death severe injury or property damage This applianc...

Page 3: ...S WARNINGS 4 PRODUCT OVERVIEW 5 PRODUCT DESCRIPTION 5 SPECIFICATIONS 5 PRODUCT FEATURES 5 HEATER INSTALLATION INSTRUCTIONS 6 CEILING WALL MOUNTING 6 CEILING RECESS 9 TUBE SUSPENSION 10 ELECTRICAL INST...

Page 4: ...nly The heater should be inspected before use and at least annually serviced inspected by a qualified licenced service person Do not perform maintenance until heater has been turned off power disconne...

Page 5: ...of any aspect of the installation contact Bromic for advice The Platinum Smart Heat Electric is designed to provide efficient spot heating for commercial and residential applications The heaters are b...

Page 6: ...tain product appearance mount heater under cover and protect from rain and weather WARNING Outdoor Installation WARNING Outdoor Installation CEILING WALL MOUNTING Heaters must be away from the fourth...

Page 7: ...m rain This is necessary to stop water entering the bracket maintain IPX4 rating 4 Ensure M6x0 6 screws are inserted into both sides of heater bracket with 6mm of the threaded shaft exposed under the...

Page 8: ...way from the opposite side of the bracket j Use angled covers if heater is angled Use straight covers if heater is not angled 10 Tighten mounting M6 screws firmly ensuring covers fit snugly against t...

Page 9: ...NING The heater must be completely protected against water contact from above 500mm 19 6 500mm 19 6 870mm 34 2 2300W 1305mm 51 4 3400W CLEARANCE TO COMBUSTIBLES OPTION 1 CLEARANCE TO COMBUSTIBLES OPTI...

Page 10: ...ve plug in wall bracket Attach extra supplied cable gland into the same hole from the outside of the bracket Fasten in place with metal cable gland nut from inside the bracket c 4 Feed heater power ca...

Page 11: ...in the slots on both sides o CEILING RECESS SOLD SEPARATELY Heater must be installed with heater surface at least 94 above the floor level Installation is identical to Ceiling Wall Mounting above Use...

Page 12: ...tal especially at locations near the coast Additional cleaning of the heater with a soft damp cloth fortnightly will aid in maintaining the product s appearance SERVICING WARNING Servicing and maitena...

Reviews: