ELECTRICAL INSTALLATION

This heater MUST be permanently installed by 

an authorised/licenced person. Do not perform 

maintenance, or carry out installation or assembly 

procedure while electrical power is switched on.  To 

disconnect heater, turn off power to heater circuit at 

main disconnect panel .

1.

Check product label for correct voltage and

 wattage to 

ensure sure power source conforms to the heaters 
requirements.

2. The power cable must positioned away from & 

protected from the enclosure of the heater.

3. Make all connections in accordance with

local electrical code regulations. For outdoor 
installation, all connections must be made in 
accordance with local electrical code regulations for 
outdoor wiring. Only use wiring components approved 
for outdoor use with minimum IPX4 rating.

WARNING

ELECTRICAL SHOCK HAZARD! Serious injury or death 

may occur. Disconnect from electrical supply before 

installing or servicing this heater. Read and follow 

installation clearance requirements outlined in this 

manual. The appliance MUST be connected to a properly 

grounded electrical source.

!

ELECTRICAL INSTALLATION

WARNING

ELECTRICAL SHOCK HAZARD!

Serious injury or death may occur. Disconnect from 

electrical supply before servicing this heater.

!

MAINTENANCE 

Ensure that the heating unit is not directly exposed to rain 
or water contact. For longest product life, and to maintain 
product appearance, mount heater under cover and protect 
from rain and weather whenever possible.  

The exterior housing of the heater should be cleaned 
regularly. To clean the appliance; ensure heater is off, and 
has been off for at least 2 hours after operation, before 
wiping off any dirt/dust with a soft damp cloth. 

Salt in the air can cause rusting of metal, especially at 
locations near the coast. Additional cleaning of the heater 
with a soft damp cloth fortnightly will aid in maintaining the 
product’s appearance.

SERVICING

WARNING

Servicing and maitenance MUST be carried out by an 
authorised and licenced service person only. Do not operate 
any heater after it malfunctions. Disconnect power at 
service panel and have heater inspected by a reputable 
electrician before reusing.

!

WARNING

If the supply cord is damaged, it must be replaced by 
Bromic, a service agent of Bromic or similarly qualified 
persons in order to avoid a hazard. Contact Bromic for 

further information on replacement of the supply cord.

!

SYMPTOM

POSSIBLE CAUSE (S)

CORRECTIVE ACTION

No heat

1. Improper connection

1. Check connection to power supply

Not enough heat

1. Heater too small for application
2. Heater mounted too high or too
far

1. Add additional heater(s)
2. Decrease mounting height or
distance

Too much heat

1. Heater too large for application
2. Heater mount too low or too close

1. Replace with smaller heater
2. Increase mounting height or
distance

TROUBLESHOOTING

For wiring instructions using Bromic Platinum Smart-Heat Electric Wireless Dimmer BH3130011-1 or ON/OFF Control 

BH3130010-1 refer to instructions provided with controller.

IMPORTANT:  Electronic dimmer controls generate heat during operation.  For Bromic heaters installed Bromic 

Smart-Heat Electric Wireless Dimmer 

BH3130011-1 

or ON/OFF Control 

BH3130010-1

 it is essential to ensure dimmers 

are mounted in a clean, dry and well ventilated position with clearance on all sides.  It must be ensured the dimmers 

are not installed in a confined space, close to other heat generating appliances or in the case of a multi-dimmer 

installation, not too close together.  Dimmers must remain cool at all times.  Please consult Bromic dimmer 

installation instructions for further details or for further questions please contact Bromic technical support services.

WARNING

!

Summary of Contents for BH0320003

Page 1: ...BY BROMIC INSTALLATION INSTRUCTION AND SERVICE MANUAL IMPORTANT READ THIS MANUAL CAREFULLY SEE INSIDE COVER FOR IMPORTANT INFORMATION ABOUT THIS MANUAL KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFE...

Page 2: ...RNING IMPORTANT READ THIS MANUAL CAREFULLY before installing or servicing this product Improper installation operation or maintenance can result in death severe injury or property damage This applianc...

Page 3: ...S WARNINGS 4 PRODUCT OVERVIEW 5 PRODUCT DESCRIPTION 5 SPECIFICATIONS 5 PRODUCT FEATURES 5 HEATER INSTALLATION INSTRUCTIONS 6 CEILING WALL MOUNTING 6 CEILING RECESS 9 TUBE SUSPENSION 10 ELECTRICAL INST...

Page 4: ...nly The heater should be inspected before use and at least annually serviced inspected by a qualified licenced service person Do not perform maintenance until heater has been turned off power disconne...

Page 5: ...of any aspect of the installation contact Bromic for advice The Platinum Smart Heat Electric is designed to provide efficient spot heating for commercial and residential applications The heaters are b...

Page 6: ...tain product appearance mount heater under cover and protect from rain and weather WARNING Outdoor Installation WARNING Outdoor Installation CEILING WALL MOUNTING Heaters must be away from the fourth...

Page 7: ...m rain This is necessary to stop water entering the bracket maintain IPX4 rating 4 Ensure M6x0 6 screws are inserted into both sides of heater bracket with 6mm of the threaded shaft exposed under the...

Page 8: ...way from the opposite side of the bracket j Use angled covers if heater is angled Use straight covers if heater is not angled 10 Tighten mounting M6 screws firmly ensuring covers fit snugly against t...

Page 9: ...NING The heater must be completely protected against water contact from above 500mm 19 6 500mm 19 6 870mm 34 2 2300W 1305mm 51 4 3400W CLEARANCE TO COMBUSTIBLES OPTION 1 CLEARANCE TO COMBUSTIBLES OPTI...

Page 10: ...ve plug in wall bracket Attach extra supplied cable gland into the same hole from the outside of the bracket Fasten in place with metal cable gland nut from inside the bracket c 4 Feed heater power ca...

Page 11: ...in the slots on both sides o CEILING RECESS SOLD SEPARATELY Heater must be installed with heater surface at least 94 above the floor level Installation is identical to Ceiling Wall Mounting above Use...

Page 12: ...tal especially at locations near the coast Additional cleaning of the heater with a soft damp cloth fortnightly will aid in maintaining the product s appearance SERVICING WARNING Servicing and maitena...

Reviews: