1. Prepare ceiling cut-out with dimensions from images on P.9
to fit ceiling recess frame (a). Heater must be installed with
heater surface at least 2400mm above the floor level, with
500mm clearance to the nearest wall on all sides of the heater.
Minimum distances to combustibles within cavity must be
according to 

only one 

of the two options shown.

2. From below, bring ceiling frame up and into ceiling cutout.
Fasten ceiling frame into cut-out at both ends and centre using
appropriate screws

 (b)

. Which locator hole to use is dictated

by the thickness of the ceiling surface. The fastening screws
must be inserted into a strong material that can easily support
the weight of the heater. Your installation may require re-
enforcing before the frame can be safely installed.

3. Unscrew and remove plug-in wall bracket. Attach extra
supplied cable gland into the same hole from the outside of
the bracket. Fasten in place with metal cable gland nut from
inside the bracket 

(c)

.

4. Feed heater power cable through cable gland from inside of
wall bracket

 (d)

.

5. Ensure M6x14mm screws are inserted into either side of
heater bracket with 6mm of the threaded shaft exposed under
the screw head. (e).

6. Insert heater bracket into mounting bracket by hooking M6
screws into place in mounting slots

 (f)

.

7. Fix heater to bracket in straight position using M4x10mm
positioning screws on either side of mounting bracket

 (g)

.

Ensure M6 screws are sitting fully in the mounting slots (as if
the heater were hanging from the wall bracket).

8. Fit the smaller, straight cover over the heater bracket so
that the slots pass over the shafts of the M6x14mm mounting
screws (h). Fit the larger cover over the smaller cover in the
same way from the opposite side of the bracket

 (i)

.

9. Tighten mounting screws firmly, ensuring covers fit snugly
against the bracket on all sides

 (j)

.

10. Firmly tighten cable gland in wall bracket so that cable
does not move when pulled.

b

d

f

e

g

h

i

c

 230 

/ 9.1 "

870

/ 34.2"

a

b

d

f

e

g

h

i

c

9.1” 

35.2”

a

b

d

f

e

g

h

i

c

a

b

d

f

e

g

h

i

c

9.1” 

35.2”

a

Summary of Contents for BH0320003

Page 1: ...BY BROMIC INSTALLATION INSTRUCTION AND SERVICE MANUAL IMPORTANT READ THIS MANUAL CAREFULLY SEE INSIDE COVER FOR IMPORTANT INFORMATION ABOUT THIS MANUAL KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFE...

Page 2: ...RNING IMPORTANT READ THIS MANUAL CAREFULLY before installing or servicing this product Improper installation operation or maintenance can result in death severe injury or property damage This applianc...

Page 3: ...S WARNINGS 4 PRODUCT OVERVIEW 5 PRODUCT DESCRIPTION 5 SPECIFICATIONS 5 PRODUCT FEATURES 5 HEATER INSTALLATION INSTRUCTIONS 6 CEILING WALL MOUNTING 6 CEILING RECESS 9 TUBE SUSPENSION 10 ELECTRICAL INST...

Page 4: ...nly The heater should be inspected before use and at least annually serviced inspected by a qualified licenced service person Do not perform maintenance until heater has been turned off power disconne...

Page 5: ...of any aspect of the installation contact Bromic for advice The Platinum Smart Heat Electric is designed to provide efficient spot heating for commercial and residential applications The heaters are b...

Page 6: ...tain product appearance mount heater under cover and protect from rain and weather WARNING Outdoor Installation WARNING Outdoor Installation CEILING WALL MOUNTING Heaters must be away from the fourth...

Page 7: ...m rain This is necessary to stop water entering the bracket maintain IPX4 rating 4 Ensure M6x0 6 screws are inserted into both sides of heater bracket with 6mm of the threaded shaft exposed under the...

Page 8: ...way from the opposite side of the bracket j Use angled covers if heater is angled Use straight covers if heater is not angled 10 Tighten mounting M6 screws firmly ensuring covers fit snugly against t...

Page 9: ...NING The heater must be completely protected against water contact from above 500mm 19 6 500mm 19 6 870mm 34 2 2300W 1305mm 51 4 3400W CLEARANCE TO COMBUSTIBLES OPTION 1 CLEARANCE TO COMBUSTIBLES OPTI...

Page 10: ...ve plug in wall bracket Attach extra supplied cable gland into the same hole from the outside of the bracket Fasten in place with metal cable gland nut from inside the bracket c 4 Feed heater power ca...

Page 11: ...in the slots on both sides o CEILING RECESS SOLD SEPARATELY Heater must be installed with heater surface at least 94 above the floor level Installation is identical to Ceiling Wall Mounting above Use...

Page 12: ...tal especially at locations near the coast Additional cleaning of the heater with a soft damp cloth fortnightly will aid in maintaining the product s appearance SERVICING WARNING Servicing and maitena...

Reviews: