Removing horizontal knockout opening on back of hood

HD0076

5. CHOOSE THE OPENING (INTERIOR BLOWER)

Remove the knockout for the chosen opening (horizontal at the back of the hood or vertical on rough-in plate). 
See pictures below.

CAUTION

When using P5 blower, remove the 10’’ wide knockout (smaller part). If using P8 blower, remove
the knockout corresponding to the ducting installed (10’’ or 14’’). 

Removing vertical knockout opening on rough-in plate

HD0077

10’’ 

KNOCKOUT

14’’ 

KNOCKOUT

14’’ 

KNOCK

OUT

10’’

 

KNOCK

OUT

6. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS)

INTERIOR BLOWER: Secure the rough-in plate (provided with the P5 and P8 blower) inside the hood with four (4) 

lock nuts. See picture below.

EXTERIOR OR IN-LINE BLOWER: Purchase Model 332KR separately. Refer to instructions included with the rough-in

kit. Secure the rough-in plate inside the hood with (4) lock nuts.

HD0042

Inserting deviator into hood vertical opening

7. INSTALL THE DEVIATOR (INTERIOR BLOWER)

YOU MUST

install the deviator if you choose to vent the hood vertically.

Install the deviator as shown.

NOTE:

If installed correctly, the deviator will protrude about 1/8” above the 
rough-in plate.

HD0003

Summary of Contents for Elite 64000 SERIES

Page 1: ...n NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 Broan NuTone Canada Inc 1140 Tristar Drive Mississauga ON L5T 1H9 1 888 882 7626 REGISTER YOUR PRODUCT ON LINE AT www broan com register V03515 rev J HB0056 INSTALLATION INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...al tray then turn off the burner BE CAREFUL TO PREVENT BURNS IF THE FLAMES DO NOT GO OUT IMMEDIATELY EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels This could cause a violent steam explosion 4 Use an extinguisher ONLY if A You own a Class ABC extinguisher and you know how to operate it B The fire is small ...

Page 3: ...E HOOD SYSTEM INTERIOR BLOWERS Flow deviator vertical exhaust only supplied with P5 and P8 blowers Model 647 7 Rd wall cap Model 634 or 644 roof cap Model 643 8 Rd wall cap 8 round standard duct Model 407 7 round 2 ft sections Model 413 transition 31 4 x 10 to 8 Model 459 transition 31 4 x 14 to 8 Model P8 dual blower 900 cfm for use with 36 hoods or wider NOTE The dual blower P8 can be installed ...

Page 4: ...er includes one 8 to 10 round transition Model 331H 600 cfm or 332H 900 cfm exterior blower Model 335 1200 cfm or 336 1500 cfm exterior blower Model 441 10 Rd wall cap Model 437 High capacity roof cap Model 441 10 Rd wall cap Model 421 10 Rd vert in line damper Recommended for use with exterior blowers Model 410 10 Rd duct 2ft sections Model HLB6 600 cfm in line blower includes two 4 x 18 to 10 ro...

Page 5: ...s than 20 for an electric range and 24 for a gas range A maximum of 30 above cooktop is highly recommended for best capture of cooking impurities Distances over 30 are at the installer and users discretion Hood with interior blower 3 x 10 or 3 x 14 duct Roof cap Wall cap HH0029A 3 x 14 to 8 transition if 3 x 14 duct 20 minimum above cooking surface 24 for gas MODEL P5 SINGLE OR P8 DOUBLE INTERIOR ...

Page 6: ... dampers wall and roof caps Refer to pages 3 and 4 for a complete list of venting options and model numbers NOTE For cabinets with recessed bottom attach wood filler strips not included on each sides as shown below Use two 2 2 inch wide strips for 30 wide hoods and four 4 2 inch wide strips for wider hoods cut to length See below for wood filler strip locations HD0079 A A B C 3 INSTALL BACKSPLASH ...

Page 7: ...KOUT 14 KNOCKOUT 10 KNOCKOUT 6 INSTALL THE ROUGH IN PLATE ALL BLOWERS INTERIOR BLOWER Secure the rough in plate provided with the P5 and P8 blower inside the hood with four 4 lock nuts See picture below EXTERIOR OR IN LINE BLOWER Purchase Model 332KR separately Refer to instructions included with the rough in kit Secure the rough in plate inside the hood with 4 lock nuts HD0042 Inserting deviator ...

Page 8: ...he cable in the hood and tighten the wire clamp to secure the cable Place the hood under the cabinet and slide it in position Make sure the adapter damper assembly enters the ducting Secure the hood by tightening the screws completely EXTERIOR OR IN LINE BLOWER Run power cable to installation location Place the hood to its location Mark the position of the screws smaller part of the key holes with...

Page 9: ...G Risk of electrical shock Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally 1 HD0007 1 Ground screw 11 INSTALL THE BLOWER INTERIOR BLOWER The blower must be installed to the rough in plate using 4 3...

Page 10: ...HOOD WILL NOT WORK PROPERLY IF REVERSED Both impellers are different in the dual blower one rotates clockwise and the other counterclockwise Each wheel and motor have an arrow and a number on them you have to match them correctly see drawing beside Install screws into the location as shown in the pictures below single blower or dual blower Do not tighten screws down fully leave a 1 8 gap Hang blow...

Page 11: ...ith center one s 1 Insert upper end of filter into the hood tab end 2 Raise lower end toward the inside of hood 3 Position lower end of filter into channel and pull on filter tab 4 While pulling the filter tab slide the filter top under the inner retaining piece Baffle filters are available as an option see instruction sheet included with baffle filters HD0009 HD0010 15 USE AND CARE Grease filters...

Page 12: ...are highly explosive and should never be used close to a range Enamel finish Clean with warm water and mild detergent only When discoloration occurs use a good enamel polish such as auto motive polish DO NOT use rough abrasive cleaner or porcelain cleaner 16 OPERATION Always turn your hood on before you begin cooking to establish an air flow in the kitchen Let the blower run for a few minutes to c...

Page 13: ...ty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone LLC faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states...

Page 14: ...HTED SINGLE SWITCH FOR BLOWER SPEED CONTROL BUTTON TERMINAL STRIP 10 POWER CORDS 10 CORDS FOR HEAT LAMP 10 CONTROL WIRE 10 LIGHTED SWITCH WIRE LOCK NUT NO 8 32 SCREW NO 8 32 x 1 2 QUADREX MACHINE SCREW NO 6 32 x 1 4 LOCK NUT NO 6 32 SCREW NO 8 3 8 T B NO 8 HEAD RANGEMASTER FILTER 8 930 x 9 800 RANGEMASTER FILTER 11 930 x 9 800 GREASE RAIL 30 GREASE RAIL 36 GREASE RAIL 42 GREASE RAIL 48 FILTER CLIP...

Page 15: ... PLATE ASSEMBLY FOAM 1 2 x 1 2 x 12 CAPACITOR 15MFD MACHINE SCREW NO 6 32 x 1 4 WIRE COVER LOCK NUT NO 6 32 SINGLE BLOWER ASSEMBLY IMPELLER RING BLOWER IMPELLER 7 094 x 3 375 CW MOTOR 165W CW WASHER 3 16 ID x 3 4 OD MOTOR GROMMET G 431 1 8 TIE WRAP MOTOR MOUNT WIRE NO 18 TEW BROWN x 10 METRIC SCREW M4 x 6MM PAN QDRX STRAIN RELIEF FOR BLOWER POWER CORD 36 BLOWER POWER CORD OUTLET BOX COVER POWER CO...

Page 16: ...TER AND DAMPER 31 4 x 10 AIR DEFLECTOR DUAL BLOWER ROUGH IN PLATE ASSEMBLY FOAM 1 2 x 1 2 x 12 LOCK NUT NO 6 32 CAPACITOR 15MFD WIRE COVER MOTOR 165W CW BLOWER IMPELLER HOOD 7 094 x 3 375 CW DUAL BLOWER ASSEMBLY IMPELLER RING BLOWER IMPELLER HOOD 7 094 x 3 375 CCW MOTOR 165W CCW WASHER 3 16 ID x 3 4 OD 8 TIE WRAP MOTOR MOUNT WIRE NO 18 TEW BROWN x 10 MOTOR GROMMET G 431 1 METRIC SCREW M4 x 6MM PAN...

Reviews: