background image

- 12 -

15. USE AND CARE 

(CONT’D)

Hood cleaning

Stainless steel cleaning: How to maintain its « BRIGHT LOOK »

Do:

- Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.

- Always clean in the direction of original polish lines.

- Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely.

- You may also use a specialized household stainless steel cleaner.

Don’t:

- Do not use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.

- Do not use any harsh or abrasive cleansers.

- Do not allow dirt to accumulate.

- Do not let plaster dust or any other construction residues reach the hood. During construction or renovation, cover 

the hood to make sure no dust sticks to stainless steel surface.

Avoid: when choosing a detergent

- Any cleaners that contain 

bleach

will attack stainless steel. 

- Any products containing :  

chloride

fluoride

iodide

bromide

will deteriorate surfaces rapidly.

- Any 

combustible products

used for cleaning such as 

acetone

alcohol

ether

benzol

, etc., are highly explosive 

and should never be used close to a range.

Enamel finish:

Clean with warm water and mild detergent only. When discoloration occurs, use a good enamel polish such as auto-
motive polish. (

DO NOT

use rough abrasive cleaner or porcelain cleaner.)

16. OPERATION

Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few
minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.

1

1

2

3

4

1) Warming lamp switches
2) Halogen light switches
3) ON/OFF blower switch
4) Blower speed control

HC0028

BLOWER

The blower is operated using two (2) controls.

Use the red, lighted on/off switch to start and stop the blower. When turned on, the blower will operate at the previous
setting of the speed control.

Turn the speed control knob clockwise to decrease blower speed – counterclockwise to increase speed.

COOKTOP LIGHTING (HALOGEN)

A double set of ON/OFF switches controls the halogen lights.

The front rocker controls the center light (for 42” and 48” hoods). The rear rocker controls both side lights (each switch
controls one light for 30” and 36” hood). Select one, two or three lights for best cooking lighting.

Use PAR 20, 50W halogen bulbs.

Summary of Contents for Elite 64000 SERIES

Page 1: ...n NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 Broan NuTone Canada Inc 1140 Tristar Drive Mississauga ON L5T 1H9 1 888 882 7626 REGISTER YOUR PRODUCT ON LINE AT www broan com register V03515 rev J HB0056 INSTALLATION INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...al tray then turn off the burner BE CAREFUL TO PREVENT BURNS IF THE FLAMES DO NOT GO OUT IMMEDIATELY EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels This could cause a violent steam explosion 4 Use an extinguisher ONLY if A You own a Class ABC extinguisher and you know how to operate it B The fire is small ...

Page 3: ...E HOOD SYSTEM INTERIOR BLOWERS Flow deviator vertical exhaust only supplied with P5 and P8 blowers Model 647 7 Rd wall cap Model 634 or 644 roof cap Model 643 8 Rd wall cap 8 round standard duct Model 407 7 round 2 ft sections Model 413 transition 31 4 x 10 to 8 Model 459 transition 31 4 x 14 to 8 Model P8 dual blower 900 cfm for use with 36 hoods or wider NOTE The dual blower P8 can be installed ...

Page 4: ...er includes one 8 to 10 round transition Model 331H 600 cfm or 332H 900 cfm exterior blower Model 335 1200 cfm or 336 1500 cfm exterior blower Model 441 10 Rd wall cap Model 437 High capacity roof cap Model 441 10 Rd wall cap Model 421 10 Rd vert in line damper Recommended for use with exterior blowers Model 410 10 Rd duct 2ft sections Model HLB6 600 cfm in line blower includes two 4 x 18 to 10 ro...

Page 5: ...s than 20 for an electric range and 24 for a gas range A maximum of 30 above cooktop is highly recommended for best capture of cooking impurities Distances over 30 are at the installer and users discretion Hood with interior blower 3 x 10 or 3 x 14 duct Roof cap Wall cap HH0029A 3 x 14 to 8 transition if 3 x 14 duct 20 minimum above cooking surface 24 for gas MODEL P5 SINGLE OR P8 DOUBLE INTERIOR ...

Page 6: ... dampers wall and roof caps Refer to pages 3 and 4 for a complete list of venting options and model numbers NOTE For cabinets with recessed bottom attach wood filler strips not included on each sides as shown below Use two 2 2 inch wide strips for 30 wide hoods and four 4 2 inch wide strips for wider hoods cut to length See below for wood filler strip locations HD0079 A A B C 3 INSTALL BACKSPLASH ...

Page 7: ...KOUT 14 KNOCKOUT 10 KNOCKOUT 6 INSTALL THE ROUGH IN PLATE ALL BLOWERS INTERIOR BLOWER Secure the rough in plate provided with the P5 and P8 blower inside the hood with four 4 lock nuts See picture below EXTERIOR OR IN LINE BLOWER Purchase Model 332KR separately Refer to instructions included with the rough in kit Secure the rough in plate inside the hood with 4 lock nuts HD0042 Inserting deviator ...

Page 8: ...he cable in the hood and tighten the wire clamp to secure the cable Place the hood under the cabinet and slide it in position Make sure the adapter damper assembly enters the ducting Secure the hood by tightening the screws completely EXTERIOR OR IN LINE BLOWER Run power cable to installation location Place the hood to its location Mark the position of the screws smaller part of the key holes with...

Page 9: ...G Risk of electrical shock Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally 1 HD0007 1 Ground screw 11 INSTALL THE BLOWER INTERIOR BLOWER The blower must be installed to the rough in plate using 4 3...

Page 10: ...HOOD WILL NOT WORK PROPERLY IF REVERSED Both impellers are different in the dual blower one rotates clockwise and the other counterclockwise Each wheel and motor have an arrow and a number on them you have to match them correctly see drawing beside Install screws into the location as shown in the pictures below single blower or dual blower Do not tighten screws down fully leave a 1 8 gap Hang blow...

Page 11: ...ith center one s 1 Insert upper end of filter into the hood tab end 2 Raise lower end toward the inside of hood 3 Position lower end of filter into channel and pull on filter tab 4 While pulling the filter tab slide the filter top under the inner retaining piece Baffle filters are available as an option see instruction sheet included with baffle filters HD0009 HD0010 15 USE AND CARE Grease filters...

Page 12: ...are highly explosive and should never be used close to a range Enamel finish Clean with warm water and mild detergent only When discoloration occurs use a good enamel polish such as auto motive polish DO NOT use rough abrasive cleaner or porcelain cleaner 16 OPERATION Always turn your hood on before you begin cooking to establish an air flow in the kitchen Let the blower run for a few minutes to c...

Page 13: ...ty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone LLC faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states...

Page 14: ...HTED SINGLE SWITCH FOR BLOWER SPEED CONTROL BUTTON TERMINAL STRIP 10 POWER CORDS 10 CORDS FOR HEAT LAMP 10 CONTROL WIRE 10 LIGHTED SWITCH WIRE LOCK NUT NO 8 32 SCREW NO 8 32 x 1 2 QUADREX MACHINE SCREW NO 6 32 x 1 4 LOCK NUT NO 6 32 SCREW NO 8 3 8 T B NO 8 HEAD RANGEMASTER FILTER 8 930 x 9 800 RANGEMASTER FILTER 11 930 x 9 800 GREASE RAIL 30 GREASE RAIL 36 GREASE RAIL 42 GREASE RAIL 48 FILTER CLIP...

Page 15: ... PLATE ASSEMBLY FOAM 1 2 x 1 2 x 12 CAPACITOR 15MFD MACHINE SCREW NO 6 32 x 1 4 WIRE COVER LOCK NUT NO 6 32 SINGLE BLOWER ASSEMBLY IMPELLER RING BLOWER IMPELLER 7 094 x 3 375 CW MOTOR 165W CW WASHER 3 16 ID x 3 4 OD MOTOR GROMMET G 431 1 8 TIE WRAP MOTOR MOUNT WIRE NO 18 TEW BROWN x 10 METRIC SCREW M4 x 6MM PAN QDRX STRAIN RELIEF FOR BLOWER POWER CORD 36 BLOWER POWER CORD OUTLET BOX COVER POWER CO...

Page 16: ...TER AND DAMPER 31 4 x 10 AIR DEFLECTOR DUAL BLOWER ROUGH IN PLATE ASSEMBLY FOAM 1 2 x 1 2 x 12 LOCK NUT NO 6 32 CAPACITOR 15MFD WIRE COVER MOTOR 165W CW BLOWER IMPELLER HOOD 7 094 x 3 375 CW DUAL BLOWER ASSEMBLY IMPELLER RING BLOWER IMPELLER HOOD 7 094 x 3 375 CCW MOTOR 165W CCW WASHER 3 16 ID x 3 4 OD 8 TIE WRAP MOTOR MOUNT WIRE NO 18 TEW BROWN x 10 MOTOR GROMMET G 431 1 METRIC SCREW M4 x 6MM PAN...

Reviews: