background image

6

 

Key No. 

Part No. 

Description

 1 

99111432 

Grille

 2 

99360253 

Knob

  3 

52872039 

Grille Screw

  4 

97018465 

Heater Assembly (9810WH)

 

 

97018466 

Heater Assembly (9815WH)

  5 

57271000 

Thermostat, with Mounting Nut

  6 

33384000 

Thermostat Cover

  7 

33178000 

Blower & Motor

  8 

 98010878 

Heat Box

  9 

35841000 

Thermal Fuse

  10 

99271433 

Thermal Protector

SERVICE PARTS

1

2

3

4

5

6

7

8

9

10

BROAN-NUTONE ONE YEAR LIMITED WARRANTY

Broan-NuTone warrants to the original consumer purchaser of its 

products that such products will be free from defects in materials 

or workmanship for a period of one year from the date of original 

purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS 

OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED 

WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A 

PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, re-

pair or replace, without charge, any product or part which is found 

to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT 

LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT 

BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS 

AND OTHER ACCESSORIES FOR DUCTING. This warranty 

does not cover (a) normal maintenance and service or (b) any 

products or parts which have been subject to misuse, negligence, 

accident, improper maintenance or repair (other than by Broan-

NuTone), faulty installation or installation contrary to recommend-

ed installation instructions.
The duration of any implied warranty is limited to the one-year pe-

riod as specified for the express warranty. Some states do not al-

low limitation on how long an implied warranty lasts, so the above 

limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, 

AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHAS-

ER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WAR-

RANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCI-

DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING 

OUT OF OR IN CONNECTION WITH PRODUCT USE OR PER-

FORMANCE. Some states do not allow the exclusion or limitation 

of incidental or consequential damages, so the above limitation or 

exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also 

have other rights, which vary from state to state. This warranty 

supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone 

at the address or telephone number below, (b) give the model 

number and part identification and (c) describe the nature of any 

defect in the product or part. At the time of requesting warranty 

service, you must present evidence of the original purchase date.

Broan-NuTone LLC 

926 W. State Street 

Hartford, Wisconsin 53027 

www.broan.com    800-558-1711 

WARRANTY

99045152B

Summary of Contents for 9810WH Series

Page 1: ...it at main disconnect panel or operate internal disconnect switch if provided 10 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater 11 To prevent a possible fire do not block air intakes or exhaust in any manner 12 A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoli...

Page 2: ... or 6 from the floor 2 Refer to Figure 2 Make wall cutout next to a wall stud Cutout size 125 8 high x 105 8 wide with frame 3 Run wiring from circuit breaker or fuse box to heater location 4 Install box connector into wiring entrance hole in housing s junction box 5 Pull wiring through cutout and secure cable to box connector Allow 6 of wiring to make connections 6 Refer to Figure 3 Insert TOP of...

Page 3: ...Volt operation make wiring connections as shown in Figure 5 4 Use wire nuts to make connections Insulate all connections with electrical tape SECURING THE HEATER 1 Dress all wiring back to into junction box 2 Locate center holes in housing flange and align with mounting holes in grille 3 Use two provided screws to attach grille to housing 4 1 2 3 4 1 2 3 FIGURE 4 FIGURE 5 120vAC 240vAC GREEN OR BA...

Page 4: ...tain desired temperature Turn the thermostat to FULL COUNTERCLOCKWISE position when operation is no longer desired Thermal protector If for any reason temperatures increase beyond normal limits a safety thermal fuse will shut heater off The heater will require servicing by a qualified electrician Check entire installation to determine cause of overheating ...

Page 5: ...ce department at 800 558 1711 LUBRICATION The heater is permanently lubricated and never needs oiling or disassembly CLEANING Clean heater once a month as follows 1 Turn off power at service panel 2 Make sure heating element is cool 3 Use a soft brush attachment to gently vacuum grille open ings or wipe grille clean with a soft cloth 4 Restore power CAUTION METAL AND ELECTRICAL PARTS SHOULD NEVER ...

Page 6: ...e negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or installation contrary to recommend ed installation instructions The duration of any implied warranty is limited to the one year pe riod as specified for the express warranty Some states do not al low limitation on how long an implied warranty lasts so the above limitation may not apply to you BRO...

Page 7: ...anel de desconexión principal o active el interruptor de desconexión interna si existe 10 No inserte ni permita que objetos extraños entren en la abertura de ventilación o de escape pues esto puede ocasionar una descarga eléctrica un incendio o daños al calentador 11 Para prevenir un posible incendio no bloquee la entrada o salida del aire de ninguna manera 12 El calentador tiene piezas calientes ...

Page 8: ...cie vertical y a una altura no menor de 15 cm 6 pulg del piso 2 Vea la figura 2 Haga el recorte de la pared al lado de un montante de la pared Tamaño del recorte 32 cm 125 8 pulg de alto x 27 cm 105 8 pulg de ancho con el armazón 3 Tienda los cables del interruptor automático de circuitos o de la caja de fusibles al sitio de instalación del calefactor 4 Instale el conector de la caja en el orifici...

Page 9: ...onexiones indicadas en la figura 5 4 Haga las conexiones con tuercas de alambre Aísle todas las conexiones con cinta eléctrica FIJACIÓN DEL CALEFACTOR 1 Empuje y arregle todos los cables de vuelta hacia la caja de conexiones 2 Ubique los orificios centrales en la brida de la cubierta y alinéelos con los orificios de montaje de la rejilla 3 Sujete la rejilla a la cubierta con los dos tornillos sumi...

Page 10: ...a temperatura deseada Para detener el funcionamiento del termostato gírelo a la posición TOTALMENTE EN SENTIDO CONTRARIO A LAS AGUJAS DEL RELOJ Protector térmico Si por cualquier motivo la temperatura sobrepasa los límites normales un fusible térmico de seguridad apagará el calefactor En ese caso un electricista calificado deberá examinar el calefactor Inspeccione la instalación completa para dete...

Page 11: ...dor está permanentemente lubricado y nunca necesitará ponerle aceite ni desarmarlo LIMPIEZA Limpie el calentador una vez al mes tal como sigue 1 Apague la energía eléctrica en el panel de servicio 2 Asegúrese de que el elemento de calefacción esté frío 3 Use un aditamento de cepillo suave para aspirar suave mente aberturas de la rejilla o limpie la rejilla con un paño suave 4 Restaure la energía e...

Page 12: ...s o mantenidos inapropiadamente por otras compañías que no sean Broan NuTone instalación defectuosa o instalación contraria a las instrucciones de instalación recomendadas La duración de cualquier garantía implícita se limita a un período de un año como se especifica en la garantía expresa Algunos estados no permiten limitaciones en cuanto al tiempo de vencimiento de una garantía implícita por lo ...

Reviews: