MOUNTING THE HOUSING

(New Construction)

Refer to Figure 1.

1.  Choose heater location. 

Make sure the heater will not be 

mounted closer than 12” from a vertical surface or 6” 
from  
the floor.

2.  Using nails or screws, mount one side of housing to wall 

stud. The flange must be flush to the stud.

3.  Run wiring from circuit breaker or fuse box to heater 

location.

4.  Install box connector into wiring entrance hole in housing’s 

junction box.

5.  Pull wiring through entrance hole and secure cable to box 

connector. Allow 6” of wiring to make connections.

6.  Finished wall opening should be 125/8” high x 105/8” wide.

JUNCTION BOX

ROUGH-IN FRAME

WALL 

CUTOUT

WALL STUDS

10

5

/

8

←  

12

5

/

8

”  

FIGURE 1

EXISTING 

CONSTRUCTION

NEW CONSTRUCTION

MOUNTING THE HOUSING

(Existing Construction)

1.  Choose heater location. Make sure the heater will not be 

mounted closer than 12” from a vertical surface or 6” from 
the floor.

2.  

Refer to Figure 2. 

Make wall cutout next to a wall stud. 

Cutout size: 125/8” high x 105/8” wide.with frame.)

3.  Run wiring from circuit breaker or fuse box to heater 

location.

4.  Install box connector into wiring entrance hole in housing’s 

junction box.

5.  Pull wiring through cutout and secure cable to box 

connector. Allow 6” of wiring to make connections.

6. 

 Refer to Figure 3.

 Insert TOP of housing into cutout first 

so that box connector clears the wall. Then, insert bottom 
of housing into cutout. 

The flange must be flush with the 

wall.

7. 

 

Use nails or screws to mount one side of housing to wall 

stud.

FIGURE 3

WALL STUDS

JUNCTION BOX

HEATER ASSMBLY

FLANGE

MOUNTING

HOLES

ROUGH-IN

BOX

“B” UNIT MOUNTING HOLE 

- TOP AND BOTTOM

INSTALLATION

WARNING: To reduce the risk of fire, do not store or use 
gasoline or other flammable vapors and liquids in the 
vicinity of the heater.

CAUTION: High temperature, risk of fire, keep electrical 
cords, drapery, furnishings, and other combustibles at 
least 3 feet (0.9 m) from the front of the heater and away 
from the side and rear.

Summary of Contents for 9810WH Series

Page 1: ...it at main disconnect panel or operate internal disconnect switch if provided 10 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater 11 To prevent a possible fire do not block air intakes or exhaust in any manner 12 A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoli...

Page 2: ... or 6 from the floor 2 Refer to Figure 2 Make wall cutout next to a wall stud Cutout size 125 8 high x 105 8 wide with frame 3 Run wiring from circuit breaker or fuse box to heater location 4 Install box connector into wiring entrance hole in housing s junction box 5 Pull wiring through cutout and secure cable to box connector Allow 6 of wiring to make connections 6 Refer to Figure 3 Insert TOP of...

Page 3: ...Volt operation make wiring connections as shown in Figure 5 4 Use wire nuts to make connections Insulate all connections with electrical tape SECURING THE HEATER 1 Dress all wiring back to into junction box 2 Locate center holes in housing flange and align with mounting holes in grille 3 Use two provided screws to attach grille to housing 4 1 2 3 4 1 2 3 FIGURE 4 FIGURE 5 120vAC 240vAC GREEN OR BA...

Page 4: ...tain desired temperature Turn the thermostat to FULL COUNTERCLOCKWISE position when operation is no longer desired Thermal protector If for any reason temperatures increase beyond normal limits a safety thermal fuse will shut heater off The heater will require servicing by a qualified electrician Check entire installation to determine cause of overheating ...

Page 5: ...ce department at 800 558 1711 LUBRICATION The heater is permanently lubricated and never needs oiling or disassembly CLEANING Clean heater once a month as follows 1 Turn off power at service panel 2 Make sure heating element is cool 3 Use a soft brush attachment to gently vacuum grille open ings or wipe grille clean with a soft cloth 4 Restore power CAUTION METAL AND ELECTRICAL PARTS SHOULD NEVER ...

Page 6: ...e negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or installation contrary to recommend ed installation instructions The duration of any implied warranty is limited to the one year pe riod as specified for the express warranty Some states do not al low limitation on how long an implied warranty lasts so the above limitation may not apply to you BRO...

Page 7: ...anel de desconexión principal o active el interruptor de desconexión interna si existe 10 No inserte ni permita que objetos extraños entren en la abertura de ventilación o de escape pues esto puede ocasionar una descarga eléctrica un incendio o daños al calentador 11 Para prevenir un posible incendio no bloquee la entrada o salida del aire de ninguna manera 12 El calentador tiene piezas calientes ...

Page 8: ...cie vertical y a una altura no menor de 15 cm 6 pulg del piso 2 Vea la figura 2 Haga el recorte de la pared al lado de un montante de la pared Tamaño del recorte 32 cm 125 8 pulg de alto x 27 cm 105 8 pulg de ancho con el armazón 3 Tienda los cables del interruptor automático de circuitos o de la caja de fusibles al sitio de instalación del calefactor 4 Instale el conector de la caja en el orifici...

Page 9: ...onexiones indicadas en la figura 5 4 Haga las conexiones con tuercas de alambre Aísle todas las conexiones con cinta eléctrica FIJACIÓN DEL CALEFACTOR 1 Empuje y arregle todos los cables de vuelta hacia la caja de conexiones 2 Ubique los orificios centrales en la brida de la cubierta y alinéelos con los orificios de montaje de la rejilla 3 Sujete la rejilla a la cubierta con los dos tornillos sumi...

Page 10: ...a temperatura deseada Para detener el funcionamiento del termostato gírelo a la posición TOTALMENTE EN SENTIDO CONTRARIO A LAS AGUJAS DEL RELOJ Protector térmico Si por cualquier motivo la temperatura sobrepasa los límites normales un fusible térmico de seguridad apagará el calefactor En ese caso un electricista calificado deberá examinar el calefactor Inspeccione la instalación completa para dete...

Page 11: ...dor está permanentemente lubricado y nunca necesitará ponerle aceite ni desarmarlo LIMPIEZA Limpie el calentador una vez al mes tal como sigue 1 Apague la energía eléctrica en el panel de servicio 2 Asegúrese de que el elemento de calefacción esté frío 3 Use un aditamento de cepillo suave para aspirar suave mente aberturas de la rejilla o limpie la rejilla con un paño suave 4 Restaure la energía e...

Page 12: ...s o mantenidos inapropiadamente por otras compañías que no sean Broan NuTone instalación defectuosa o instalación contraria a las instrucciones de instalación recomendadas La duración de cualquier garantía implícita se limita a un período de un año como se especifica en la garantía expresa Algunos estados no permiten limitaciones en cuanto al tiempo de vencimiento de una garantía implícita por lo ...

Reviews: